Agilent 1100 Series Manuals

ManualLib has 154 documents for the Agilent 1100 Series: 5 user manuals, 14 product leaflets, 74 application notes, 7 others. Every file can be read online or downloaded as a PDF for free.

User Manual 5Product Leaflet 14Application Note 74Other 7

Key facts

Brand
Agilent
Model
1100 Series
Documents
154
Languages
EN · ES · JA · IT · DE · FR
Last added
2023-10-16

Start here

Agilent 1100 Series Fluorescence Detector Reference Manual

Agilent 1100 Series Fluorescence Detector Reference Manual

User Manual 346 pages · 6.1 MB · EN

This document serves as a comprehensive reference guide for the Agilent 1100 Series Fluorescence Detector. It provides detailed instructions on installing the hardware, setting up flow connections, and optimizing detection parameters for fluorescence and phosphorescence applications. The guide is applicable to software revisions A.01.xx.

Read online

Agilent 1100 Series specifications

Weight11.5 kg (26 lbs)
Line voltage100 – 120 or 220 – 240 VAC
Power consumption180 VA / 70 W
Maximum Ambient operating temperature0 – 40 °C
Operating altitudeUp to 2000 m

Source: Agilent 1100 Series Fluorescence Detector Reference Manual

All Agilent 1100 Series documents by type

Application Note 74

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

Which software revisions is this manual valid for?

This guide is valid for A.01.xx revisions of the Agilent 1100 Series Fluorescence Detector software.

From: Agilent 1100 Series Fluorescence Detector Reference Manual

What safety standards does the detector meet?

The detector complies with IEC, CSA, UL, and EN safety standards.

From: Agilent 1100 Series Fluorescence Detector Reference Manual

How many samples can be processed automatically using 384-well plates?

Using 384-well plates, it is possible to process up to 768 samples.

From: Agilent 1100 Series High-Throughput LC/MS System Product Leaflet

What is the range of flow rates supported by the Agilent 1100 Series pump?

The pump supports a flow rate range from 0.05 mL/min to 50 mL/min.

From: Agilent 1100 Series High-Throughput LC/MS System Product Leaflet

What is the flow rate range of the Agilent 1100 Series Capillary LC System?

The system supports high-precision delivery from 1 µL/min to 100 µL/min in capillary mode, and up to 8.5 mL/min in standard mode.

From: Agilent 1100 Series Capillary LC System Brochure

Can the Agilent 1100 Series be used as a conventional LC system?

Yes, the system is designed to be used as both a capillary LC system and a conventional LC system.

From: Agilent 1100 Series Capillary LC System Brochure