Agilent 7890 GC Manuals

ManualLib has 3 documents for the Agilent 7890 GC: 1 application note, 2 product leaflets. Every file can be read online or downloaded as a PDF for free.

Application Note 1Product Leaflet 2

Key facts

Brand
Agilent
Model
7890 GC
Documents
3
Languages
JA · EN
Last added
2012-07-06

Start here

Agilent GC/MS Simultaneous Analysis of 85 Water Quality Pesticides

Agilent GC/MS Simultaneous Analysis of 85 Water Quality Pesticides

Application Note 2 pages · 208 KB · JA

This document reports the results of a simultaneous analysis of 85 water quality regulated pesticides, including organophosphate oxon bodies and oxidation products of fenitrothion. The analysis was performed using an Agilent 7890 GC/5975C TAD MSD with 7693 ALS system. This manual is written in Japanese.

Read online

Agilent 7890 GC specifications

DeviceAgilent 7890 GC/5975C TAD MSD with 7693 ALS
ColumnHP-5msi 30m, 0.25mm, 0.25um
Injection Volume2ul
Pulse Pressure30psi 1min
Purge Off Time1min
Injector Temperature250C
Interface Temperature280C
Ion Source Temperature250C

Source: Agilent GC/MS Simultaneous Analysis of 85 Water Quality Pesticides

All Agilent 7890 GC documents by type

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

How many water quality regulated pesticides were analyzed?

The document reports a simultaneous analysis of 85 components.

From: Agilent GC/MS Simultaneous Analysis of 85 Water Quality Pesticides

What is the detection limit concentration used in the study?

The standard solution concentration used was 5ppb.

From: Agilent GC/MS Simultaneous Analysis of 85 Water Quality Pesticides

What is the minimum detection limit for 2-MIB and geosmin using this system?

The system can detect both compounds at a concentration of 1 ppt.

From: Agilent 7890A/5975CTAD Stratum System Product Leaflet

How much time does one analysis cycle take with the optimized Stratum method?

The cycle time is reduced to 20 minutes, allowing for three samples per hour.

From: Agilent 7890A/5975CTAD Stratum System Product Leaflet

How much faster are analysis times with this system?

The system provides up to three-fold faster analysis times.

From: Agilent 7890 GC/6540 QTOF LC/MS System with GC-APCI Interface Technical Overview

What is the maximum column gas flow increase compared to dedicated GC systems?

The outlet and inlet are at atmospheric pressure, allowing as much as five times higher column gas flow than dedicated GC systems.

From: Agilent 7890 GC/6540 QTOF LC/MS System with GC-APCI Interface Technical Overview