Agilent W DB-5ms Manuals

ManualLib has 7 documents for the Agilent W DB-5ms: 7 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 7

Key facts

Brand
Agilent
Model
W DB-5ms
Documents
7
Languages
EN
Last added
2012-07-05

Start here

Agilent B18_PAH analysis. GC columns selection best practices for success Manual

Agilent B18_PAH analysis. GC columns selection best practices for success Manual

Application Note 1 pages · 485 KB · EN

The document addresses the analysis of polycyclic aromatic hydrocarbons (PAHs), which form from incomplete combustion of organic fuels like coal, petroleum, and wood. It highlights the regulatory differences between European Union 15+1 and US-EPA lists regarding PAH contamination in food supplies versus environmental sources.

The text focuses on selecting appropriate capillary GC columns for these analytes, comparing non-polar phases (effective for lower boiling compounds) with moderately polar phases (better for heavier EU-listed compounds). It specifically evaluates the Agilent J&W DB-EUPAH and DB-5ms columns for resolving complex mixtures of PAHs.

Read online

Agilent W DB-5ms specifications

Column Length15 m
Column Inner Diameter0.25 mm
Column Film Thickness0.25 µm
Column Part Number122-5512UI
Carrier Gas Flow Rate72 cm/s
Inlet Temperature325 °C
Oven Temperature Range150 to 325 °C
MSD Source Temperature300 °C

Source: Agilent J&W DB-5ms Ultra Inert Capillary GC Column PBDE Analysis Application Note

All Agilent W DB-5ms documents by type

Questions answered in these manuals

Which Agilent column resolves combined EU and US-EPA PAHs in under 28 minutes?

The Agilent J&W DB-EUPAH column resolves combined EU and US-EPA regulated PAHs in under 28 minutes.

From: Agilent B18_PAH analysis. GC columns selection best practices for success Manual

Which Agilent column resolves 23 of 24 EU and US-EPA regulated PAHs in under 22 minutes?

The Agilent J&W DB-5ms column resolves 23 of 24 EU and US-EPA regulated PAHs in under 22 minutes.

From: Agilent B18_PAH analysis. GC columns selection best practices for success Manual

What specific compounds were used to test the column's performance with basic analytes?

The study analyzed a mixture containing Triethylamine, Pyridine, 4-Methylpyridine, N.N-Dimethylacetamide, 2,4-Dimethylaniline, and Dicyclohexylamine.

From: Agilent J&W DB-5ms Ultra Inert Column Application Note

What is the length of the Agilent J&W DB-5ms Ultra Inert column used in this study?

The column dimensions are 30 m x 0.25 mm x 0.25 um.

From: Agilent J&W DB-5ms Ultra Inert Column Application Note

Which Agilent column is recommended for challenging PBDE analysis?

The document recommends the Agilent J&W DB-5ms Ultra Inert capillary GC column.

From: Agilent J&W DB-5ms Ultra Inert Capillary GC Column PBDE Analysis Application Note

What are the concentration ranges used for BDE calibration?

The study used a range of 0.5 to 250 ng/mL for most BDEs and 2.5 to 1,000 ng/mL for BDE-209.

From: Agilent J&W DB-5ms Ultra Inert Capillary GC Column PBDE Analysis Application Note