Key facts
- Brand
- Agilent
- Model
- W DB-5ms
- Documents
- 7
- Languages
- EN
- Last added
- 2012-07-05
Start here

Agilent B18_PAH analysis. GC columns selection best practices for success Manual
The document addresses the analysis of polycyclic aromatic hydrocarbons (PAHs), which form from incomplete combustion of organic fuels like coal, petroleum, and wood. It highlights the regulatory differences between European Union 15+1 and US-EPA lists regarding PAH contamination in food supplies versus environmental sources.
The text focuses on selecting appropriate capillary GC columns for these analytes, comparing non-polar phases (effective for lower boiling compounds) with moderately polar phases (better for heavier EU-listed compounds). It specifically evaluates the Agilent J&W DB-EUPAH and DB-5ms columns for resolving complex mixtures of PAHs.
Agilent W DB-5ms specifications
| Column Length | 15 m |
|---|---|
| Column Inner Diameter | 0.25 mm |
| Column Film Thickness | 0.25 µm |
| Column Part Number | 122-5512UI |
| Carrier Gas Flow Rate | 72 cm/s |
| Inlet Temperature | 325 °C |
| Oven Temperature Range | 150 to 325 °C |
| MSD Source Temperature | 300 °C |
Source: Agilent J&W DB-5ms Ultra Inert Capillary GC Column PBDE Analysis Application Note
All Agilent W DB-5ms documents by type
How to use the product for one specific task, with worked examples.
- Agilent B18_PAH analysis. GC columns selection best practices for success Manual 1 p
- Agilent J&W DB-5ms Ultra Inert Column Application Note 8 p
- Agilent J&W DB-5ms Ultra Inert Capillary GC Column PBDE Analysis Application Note 6 p
- Agilent Trace-Level Analysis of Melamine in Milk Products on Agilent 7890A/5975C GC/MSD Using a New Agilent J W DB-5ms Ultra Inert Column SampliQ SCX Cartridges Manual 6 p
- Agilent J&W DB-5ms Ultra Inert Capillary GC Column Application Note for Organophosphorus Pesticides Analysis 8 p
- Agilent J&W DB-5ms Ultra Inert Capillary GC Column Application Brief for PAH Analysis 2 p
- Agilent J&W DB-5ms Ultra Inert GC Column PBDE Analysis Application Note 2 p
Questions answered in these manuals
Which Agilent column resolves combined EU and US-EPA PAHs in under 28 minutes?
The Agilent J&W DB-EUPAH column resolves combined EU and US-EPA regulated PAHs in under 28 minutes.
From: Agilent B18_PAH analysis. GC columns selection best practices for success Manual
Which Agilent column resolves 23 of 24 EU and US-EPA regulated PAHs in under 22 minutes?
The Agilent J&W DB-5ms column resolves 23 of 24 EU and US-EPA regulated PAHs in under 22 minutes.
From: Agilent B18_PAH analysis. GC columns selection best practices for success Manual
What specific compounds were used to test the column's performance with basic analytes?
The study analyzed a mixture containing Triethylamine, Pyridine, 4-Methylpyridine, N.N-Dimethylacetamide, 2,4-Dimethylaniline, and Dicyclohexylamine.
From: Agilent J&W DB-5ms Ultra Inert Column Application Note
What is the length of the Agilent J&W DB-5ms Ultra Inert column used in this study?
The column dimensions are 30 m x 0.25 mm x 0.25 um.
From: Agilent J&W DB-5ms Ultra Inert Column Application Note
Which Agilent column is recommended for challenging PBDE analysis?
The document recommends the Agilent J&W DB-5ms Ultra Inert capillary GC column.
From: Agilent J&W DB-5ms Ultra Inert Capillary GC Column PBDE Analysis Application Note
What are the concentration ranges used for BDE calibration?
The study used a range of 0.5 to 250 ng/mL for most BDEs and 2.5 to 1,000 ng/mL for BDE-209.
From: Agilent J&W DB-5ms Ultra Inert Capillary GC Column PBDE Analysis Application Note