Agilent 1290 Infinity Autosampler Manuals

ManualLib has 5 documents for the Agilent 1290 Infinity Autosampler: 3 product leaflets, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 3User Manual 1

Key facts

Brand
Agilent
Model
1290 Infinity Autosampler
Documents
5
Languages
EN
Last added
2012-07-05

Start here

Agilent 1290 Infinity Autosampler User Manual

Agilent 1290 Infinity Autosampler User Manual

User Manual 210 pages · 4.2 MB · EN

The Agilent 1290 Infinity Autosampler is a laboratory instrument designed to automate sample injection in High-Performance Liquid Chromatography (HPLC) systems. This user manual covers the complete lifecycle of the device, from unpacking and site requirements to daily operation and performance optimization.

Read online

Agilent 1290 Infinity Autosampler specifications

Injection volume range0.1 to 20 pL (40 pL optional)
Temperature control range4 to 40 °C
Carryover< 0.003%
Minimum accessible sample volume1 pL from 3 pL

Source: Agilent 1290 Infinity Autosampler Performance Characteristics Technical Note

All Agilent 1290 Infinity Autosampler documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the injection volume range of the Agilent 1290 Infinity Autosampler?

The autosampler can inject precisely over a range of 0.1 pL to 20 pL, or optionally up to 40 pL.

From: Agilent 1290 Infinity Autosampler Performance Characteristics Technical Note

How does the autosampler handle thermally-labile samples?

It features a new cartridge loop design with Peltier temperature control from 4 to 40 °C.

From: Agilent 1290 Infinity Autosampler Performance Characteristics Technical Note

What is the maximum injection volume with the large volume kit?

The maximum injection volume can be increased to 120 pL at full power range.

From: Agilent 1290 Infinity Autosampler Technical Overview: Enhancing Maximum Injection Volume to 120 pL

What are the correlation coefficients for linearity?

All correlation coefficients are higher than 0.99982.

From: Agilent 1290 Infinity Autosampler Technical Overview: Enhancing Maximum Injection Volume to 120 pL

What is the maximum operating pressure for the 1290 Infinity Autosampler?

The autosampler is compatible with operating pressures up to 1200 bar.

From: Agilent 1290 Infinity Autosampler Features and Specifications

Does the 1290 Infinity Autosampler require changing sample loops for different volumes?

No, it features a next-generation flow-through design for high precision injection without the need to change sample loops.

From: Agilent 1290 Infinity Autosampler Features and Specifications