Agilent 6540 UHD Manuals

ManualLib has 3 documents for the Agilent 6540 UHD (Other Electronics): 3 product leaflets. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 3

Key facts

Brand
Agilent
Model
6540 UHD
Documents
3
Languages
EN
Last added
2012-07-05

Start here

Agilent 6540 UHD Q-TOF Technical Overview

Agilent 6540 UHD Q-TOF Technical Overview

Product Leaflet 4 pages · 203 KB · EN

This document presents a technical comparison between the Agilent 6540 Ultra High Definition (UHD) Accurate-Mass Q-TOF LC/MS system and the Thermo Scientific LTO Orbitrap XL. It focuses on the performance of the Agilent system when used at high data acquisition rates required for fast Ultra High Performance Liquid Chromatography (UHPLC) analyses.

The study demonstrates that the Agilent 6540 UHD Q-TOF maintains high resolution even at very high acquisition rates, whereas the Thermo LTQ Orbitrap XL resolution drops precipitously as acquisition speeds increase. The document concludes that the Agilent system delivers up to ten-fold better resolving power than the Orbitrap XL for this specific application, while maintaining sensitivity, dynamic range, mass accuracy, and isotopic fidelity.

Read online

Agilent 6540 UHD specifications

In-spectrum dynamic range (Agilent 6540 UHD O-TOF)50,000 to 100,000
In-spectrum dynamic range (Thermo LTO Orbitrap XL)800
Resolution mode for comparison15,000
Acquisition rate for comparison3.3 spectra/sec

Source: Agilent 6540 UHD Q-TOF LC/MS Technical Overview

All Agilent 6540 UHD documents by type

Questions answered in these manuals

What is the minimum number of data points a chromatographer would accept for a peptide peak?

The minimum acceptable number of data points across a peak is 10 to 12.

From: Agilent 6540 UHD Q-TOF Technical Overview

What resolution does the Thermo LTO Orbitrap XL achieve at an acquisition rate of 5 spectra/second?

At 5 spectra/second, the Thermo LTO Orbitrap XL resolution drops below 10,000 over the examined mass range.

From: Agilent 6540 UHD Q-TOF Technical Overview

What isotope ratio error level does the Agilent 6540 UHD O-TOF demonstrate?

The system shows a consistently low relative isotope abundance (RIA) error of about 5%.

From: Agilent 6540 UHD Q-TOF Technical Overview

How does the Agilent MFG software use data to generate molecular formulas?

The software considers the accurate mass of the parent ion, isotope abundance distribution, and mass spacing between isotope peaks.

From: Agilent 6540 UHD Q-TOF Technical Overview

What is the in-spectrum dynamic range of the Agilent 6540 UHD Q-TOF?

The Agilent 6540 UHD Q-TOF demonstrates an in-spectrum dynamic range of 50,000 to 100,000.

From: Agilent 6540 UHD Q-TOF LC/MS Technical Overview

What is the in-spectrum dynamic range of the Agilent 6540 UHD Q-TOF LC/MS system?

The system demonstrated an in-spectrum dynamic range of 50,000 to 100,000.

From: Agilent 6540 UHD Q-TOF LC/MS Technical Overview