Agilent 6890 Manuals

ManualLib has 51 documents for the Agilent 6890 (Analyzers): 5 service manuals, 9 application notes, 7 user manuals, 19 installation guides, 1 other. Every file can be read online or downloaded as a PDF for free.

Service Manual 5Application Note 9User Manual 7Installation Guide 19Other 1

Key facts

Brand
Agilent
Model
6890
Category
Analyzers
Industry
Industrial
Documents
51
Languages
EN · FR · DE · IT · JA · ES · ZH
Last added
2026-11-11

Start here

Agilent 6890N Gas Chromatograph User Guide

Agilent 6890N Gas Chromatograph User Guide

User Manual 794 pages · 22 MB · FR

This document is the User Guide for the Agilent 6890N Gas Chromatograph, published in April 2001. It provides comprehensive instructions for the preparation of the site, installation, and basic operational tasks such as controlling flow rates, pressures, and valves. The guide details the use of various injectors and detectors, including the Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD), and Nitrogen-Phosphorus Detector (NPD). This manual is written in French.

Read online

Agilent 6890 specifications

Retention time match tolerance0.02 minutes
Column dimensions10m x 0.53 mm, 0.88 um
Carrier gasHelium
Oven program range35 °C to 375 °C

Source: Agilent 6890 Series Gas Chromatography Retention Time Locking Application Note

All Agilent 6890 documents by type

Questions answered in these manuals

What does the Agilent 6890 maintenance manual cover?

It covers routine maintenance tasks for the 6890 Gas Chromatograph, with chapters on capillary columns, inlets, detectors, and valves.

From: Agilent 6890 Gas Chromatograph Maintenance Manual

What basic knowledge is assumed before performing maintenance?

The procedures assume basic knowledge of tool use and GC operation, including safely turning devices on and off, loading methods, and changing temperatures, flows, and pressures.

From: Agilent 6890 Gas Chromatograph Maintenance Manual

What is retention time locking used for in simulated distillation?

It is used to lock retention times when transferring methods between chromatographic instruments, between columns, and when changing to a different type of detector.

From: Agilent 6890 Series Gas Chromatography Retention Time Locking Application Note

How does RTL software improve data comparison?

It allows for a common universal boiling point calibration curve based on locked GC systems, which saves time and increases the value of the data.

From: Agilent 6890 Series Gas Chromatography Retention Time Locking Application Note

What is the minimum concentration of hydrocarbon impurities that can be easily detected in ethylene and propylene?

Impurity levels below 10 ppm (mole) were easily detected in both ethylene and propylene.

From: Agilent 6890 Series Trace Hydrocarbon Impurities in Ethylene Propylene Application Note

What is the split ratio used for analyzing the propylene calibration standard shown in Figure 6?

The sample was analyzed at a split ratio of 20/1.

From: Agilent 6890 Series Trace Hydrocarbon Impurities in Ethylene Propylene Application Note