Key facts
- Brand
- Agilent
- Model
- 490
- Industry
- Industrial
- Documents
- 41
- Languages
- PT · ZH · FR · EN · DE · IT · ES
- Last added
- 2026-10-18
Start here

Agilent G4900DA SureScan Microarray Scanner System User Manual
This manual covers the Agilent SureScan-Microarray-Scannersystem, including the scanner hardware, computer workstation, and control software. It provides instructions for initial setup, safe operation, and scanning slides using the SureScan control program. The document details how to configure scan protocols, manage slide queues, and utilize various scan control tools. This manual is written in German.
Read onlineAgilent 490 specifications
| Detection Limit (WCOT columns) | 0.5 ppm |
|---|---|
| Detection Limit (PLOT columns) | 2 ppm |
| Injection Volume Range | 1 μL to 10 μL |
| Injector Temperature Limit | 110° C |
| Carrier Gas Consumption Reduction | ~10% vs Benchtop GC |
All Agilent 490 documents by type
- Agilent Micro GC 490 Gas Analyzer Product Brochure 12 p
- Agilent 6490 Triple Quadrupole LC/MS System Product Leaflet 8 p
- Agilent CP-4900 Micro-GC Fast Analysis of Low Level BTEX Manual 3 p
- Varian 490-GC Sulfur in Gas Analyzer Product Leaflet 2 p
- Agilent CP-4900/450-GC Gas Chromatograph Custom Solutions Brochure 4 p
- Varian 490-GC Anesthetic Gas Analyzer Product Leaflet 2 p
- Varian 490-GC Mercaptans in Gas Analyzer Product Leaflet 2 p
- Agilent 490-GC PRO Micro-GC for Process Monitoring Product Leaflet 4 p
- Agilent 490-GC Micro-GC Product Leaflet 8 p
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Agilent 490 Micro Gas Chromatograph User Manual 122 p
- Agilent 490 Micro-GC Biogas Analyzer User Manual 12 p
- Agilent G4900DA SureScan Microarray Scanner System User Manual 144 p
- Agilent 490 Biogas Analyzer Micro GC User Manual 12 p
- Agilent G4900DA Microarray Scanner SureScan User Guide 136 p
- Agilent G4900DA SureScan Microarray Scanner System User Guide 134 p
Ratings, dimensions and ordering codes, for selection and design work.
How to use the product for one specific task, with worked examples.
- Varian CP-4900 DMD Micro-GC Application Note for Dichloroethane Analysis 2 p
- Agilent 490 Micro GC Application Note: Permanent Gases on a COX Module 4 p
- Agilent 490 Micro GC Application Note for tert-Butyl Mercaptan Analysis 2 p
- Analysis of Acetone n-Hexane MIBK MNBK MIBC Using the Agilent 490 Micro GC Application Note 2 p
- Agilent 490 Micro GC Permanent Gas Analysis Application Note 2 p
- Agilent 490 Micro GC Application Note: Fast Separation of Oxygen and Nitrogen on MolSieve 5A Channel 2 p
- Agilent Mine Gas Analysis Using the 490-GC Micro-GC Manual 3 p
- Agilent 490 Micro GC Application Note for Tetrahydrothiophene Analysis 2 p
- Agilent 490 Micro GC Analysis of Volatile Solvents on CP-Sil 5 CB Application Note 2 p
- Agilent 490 Micro GC Application Note for MES Analysis in Natural Gas 2 p
- Agilent 6490 Triple Quadrupole LC/MS tMRM Application Note 4 p
- Agilent Fast Refinery Gas Analysis Using the 490-GC Micro-GC QUAD 6 p
- Agilent 490 Micro GC Application Note for Acetone, Methanol, and Ethanol Analysis in Air 2 p
- Agilent 6490 QQQ with iFunnel Technology Application Note 4 p
- Agilent 490 Micro GC C1-C3 Hydrocarbon Analysis Application Note 2 p
- Agilent 6490 Triple Quadrupole LC/MS Application Note for Steroid Detection in Wastewaters 10 p
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the detection limit for WCOT columns?
The micro-machined thermal conductivity detector achieves a detection limit of 0.5 ppm for specific WCOT capillary columns.
Can the instrument be configured with multiple channels?
Yes, the system can be customized with up to four exclusive columns executed in parallel, each with its own calibration and settings.
How do I reset the IP address to factory defaults?
The manual provides a procedure titled “恢复出厂默认 IP 地址” that restores the instrument’s network settings to the original factory configuration.
What are the power supply specifications for the 490 Micro GC?
The instrument requires an input voltage of 85‑264 Vac, frequency 47‑63 Hz, and supplies 12.0 Vdc at up to 180 W output.
What dilution factor allows for the direct analysis of precipitated plasma?
The system enables direct analysis after diluting the sample four times in water.
From: Agilent 6490 Triple Quadrupole LC/MS System Product Leaflet
How long does it take to analyze a 96-well plate using high-speed automation?
You can analyze samples from a 96-well plate in less than 10 minutes.
From: Agilent 6490 Triple Quadrupole LC/MS System Product Leaflet