Key facts
- Brand
- Agilent
- Model
- 8800
- Industry
- Industrial
- Documents
- 9
- Languages
- ZH · EN · ES
- Last added
- 2026-10-21
Start here

Agilent SureCycler 8800 Configuration and Use Guide
This document is a configuration and use guide for the Agilent SureCycler 8800 thermocycler. It provides instructions on how to program PCR protocols, manage user accounts via the touchscreen interface, and configure network settings for remote access.
The manual covers the complete lifecycle of the instrument, including installation steps such as selecting a location and connecting power, loading samples into plastic containers or microplates, and performing routine maintenance like cleaning and fuse replacement. This manual is written in Spanish.
Agilent 8800 specifications
| Maximum Block Ramp Rate (96-well) | 6° C/sec |
|---|---|
| Block Temperature Range | 4-99° C |
| Temperature Accuracy | +0.2° C (@95° C) |
| Gradient Temperature Range | 30-90° C |
| Volume Capacity (96-well) | 10-100 pL |
| Memory Capacity | 10,000 protocols |
Source: Agilent SureCycler 8800 PCR Instrumentation and Reagents Catalog
All Agilent 8800 documents by type
How to use the product for one specific task, with worked examples.
Disassembly, diagnostics and part numbers, for repair.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the main advantage of Agilent 8800 ICP-MS/MS over conventional ICP-QMS?
It uses a triple quadrupole configuration with two independent mass selection steps to eliminate challenging mass spectral overlaps.
What reaction system is used in the Agilent 8800?
The instrument uses an octopole reaction system (ORS3) located between two quadrupole mass filters.
What email address should I use for technical support in the US and Canada?
You can contact Agilent technical services by emailing [email protected].
From: Agilent SureCycler 8800 Technical Support Contact Card
What is the phone number for technical support in Japan?
The provided text lists an email address for Japan but does not state a phone number.
From: Agilent SureCycler 8800 Technical Support Contact Card
What is the error rate of PfuUltra II Fusion HotStart DNA Polymerase?
It has an extreme accuracy with an average error rate of 1 in 2.5 million base pairs.
From: Agilent SureCycler 8800 PCR Instrumentation and Reagents Catalog
Can the SureCycler 8800 be controlled remotely?
Yes, it allows users to start, stop, program, and monitor experiments from any web-enabled device.
From: Agilent SureCycler 8800 PCR Instrumentation and Reagents Catalog