Key facts
- Brand
- Agilent
- Model
- Turbo-V 1000HT
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2026-11-07
Start here

Agilent Turbo-V 1000HT Controller User Manual
The Agilent Turbo-V 1000HT Controller is a device designed to control Turbo-V pumps. It supports multiple input voltages (100, 120, 220, 240 Vac) and provides outputs for water or air cooling, with a nominal output voltage of 56 Vac. The controller features optoisolator inputs and outputs for logic signals and drives accessories like fans and forepump coils via specific connectors.
Read onlineAll Agilent Turbo-V 1000HT documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How does the controller handle high gas loads?
The controller automatically decreases output frequency and voltage to slow down the pump in proportion to the gas load.
What is the maximum power output for the Turbo-V 1000HT Controller with water cooling?
The maximum power output is 450 W when using water cooling.
What is the voltage rating for Model 969-9454?
Model 969-9454 is prepared for 220 Vac.
From: Agilent Turbo-V 1000HT Controller Instruction Manual Model 969-9454/9554
What is the voltage rating for Model 969-9554?
Model 969-9554 is prepared for 120 Vac.
From: Agilent Turbo-V 1000HT Controller Instruction Manual Model 969-9454/9554
Is the transformer included with the controller?
No, the controller must be powered by an external transformer which is not supplied with the unit.
From: Agilent Turbo-V 1000HT PCB Controller Model 969-9879 User Manual
What is the Turbo-V 1000HT PCB Controller?
It is a frequency converter controlled by a microprocessor that incorporates circuitry for the automatic operation of Turbo-V 1000HT PCB pumps.