Key facts
- Brand
- Agilent
- Model
- 1260 Infinity II
- Category
- Industrial Robot
- Documents
- 4
- Languages
- JA · ZH · EN
- Last added
- 2026-11-01
Start here

Agilent InfinityLab LC Series Diode Array Detectors User Manual
This document serves as the user manual for the Agilent InfinityLab LC Series Diode Array Detectors, specifically covering the G7117A, G7117B, and G7117C models. It provides comprehensive guidance on instrument overview, site requirements, and operational parameters including configuration via Agilent Open Lab ChemStation. The text details the optical system, operating principles, and features such as RFID tracking for lamps and flow cells, as well as programmable slit widths for specific models.
Read onlineAgilent 1260 Infinity II specifications
| Software | Agilent OpenLab CDS, Version 2.6 |
|---|---|
| Column | Agilent InfinityLab Poroshell 120 EC-C18, 2.1 × 30 mm, 1.9 µm |
| Detection Wavelength | 290 ± 4 nm |
| Flow Rate | 1.3 mL/min |
Source: Agilent 1260 Infinity II Online Sample Manager Control Manual
All Agilent 1260 Infinity II documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What software is used to control the pumps?
Agilent OpenLab CDS, Version 2.6, is used to manage the pumps and sampling devices.
From: Agilent 1260 Infinity II Online Sample Manager Control Manual
What is the detection wavelength for the system?
The detection wavelength is 290 ± 4 nm.
From: Agilent 1260 Infinity II Online Sample Manager Control Manual
What system does this spare parts guide cover?
This guide covers the Agilent 1260 Infinity II Prime system.
From: Agilent 1260 Infinity II Prime InfinityLab Spare Parts Quick Reference Guide
Where can I find more information about these parts?
More information is available at the Agilent website.
From: Agilent 1260 Infinity II Prime InfinityLab Spare Parts Quick Reference Guide
What is the recommended sample volume for complete loop filling?
Use at least two to three times the loop volume, for example 40 – 60 μL of sample for a 20 μL sample loop.
From: Agilent 1260 Infinity II Manual Preparative Injector Technical Note
How should the syringe be removed after injection?
Leave the syringe in the needle port and turn the handle to the INJECT position before removing it.
From: Agilent 1260 Infinity II Manual Preparative Injector Technical Note
