Start here

Agilent 1200 Series Handheld Control Module Quick Reference Guide
This document serves as a quick reference guide for the Agilent 1200 Series Handheld Control Module. It outlines the primary functionality of the module within an LC system, including control over pumps, autosamplers, detectors, and temperature compartments.
The guide provides visual representations and descriptions of the main screen views available on the handheld device, such as Samples, Analysis, Status, System, and Main Views. It also lists specific functions accessible via buttons for tasks like valve bypass, syringe home, needle movement, and lamp control.
Agilent 1200 Series specifications
| Column Efficiency | 90,000 plates in 4 minutes |
|---|---|
| Column Length Options | 150, 100, 75, 50, 30 and 20 mm |
| Column Internal Diameters | 4.6, 3 and 2.1 mm |
| Temperature Zones | up to 6 independent zones |
All Agilent 1200 Series documents by type
- Agilent 1200 Series LC Solutions Product Leaflet 8 p
- Agilent 1200 Series LC Solutions Product Leaflet 8 p
- Agilent 1200 Series LC Systems Product Brochure 24 p
- Agilent 1200 Series Diode-Array Detector SL Technical Note 4 p
- Agilent 1200 Series column compartment SL with temperature control up to 100 C post-column cooling for lowerst baseline noise Manual 4 p
- Agilent 3rd Party Agilent 1200 Series Instrument Control - Applied Biosystems Analyst Manual 1 p
- Agilent 3rd Party Agilent 1200 Series Instrument Control - Dionex Chromeleon Manual 1 p
- Agilent 3rd Party Agilent 1200 Series Instrument Control - Varian Galaxy Manual 1 p
- Agilent 3rd Party Agilent 1200 Series Instrument Control - Waters Empower Manual 1 p
- Agilent 3rd Party Agilent 1200 Series Instrument Control - Waters Empower2 Manual 1 p
- Agilent 1200 Series Instant Pilot Product Leaflet 4 p
- Agilent 1200 Series Fraction Collectors Product Brochure 4 p
- Agilent 1200 Series Diode Array Detector Method Transfer Technical Note 8 p
- Agilent Reducing HPLC Solvent Consumption Technical Note 8 p
- Agilent 1200 Series ELSD Mobile Phase Compensation Technical Note 4 p
- Agilent RRLC Impurity Profiling Technical Note 8 p
- Agilent 1200 Series LC System Application Note: Structure Elucidation of Impurities with LC/MS 8 p
How to use the product for one specific task, with worked examples.
- Agilent 1200/6200 Series Application Note: Structure Elucidation of Ginsenosides 8 p
- Agilent Configuring a mass-based fraction collection system for highest purity Application Note 8 p
- Agilent 1200 Series LC/MS Application Note for Ginseng Analysis 8 p
- Agilent Fast Ultra-Fast Analysis Using the Agilent 1200 Series Rapid Resolution LC System Compared to a Conventional Agilent 1100 Series LC System 8 p
- Agilent More speed better resolution lower LOD using liquid chromatography fluorescence detection - Comparing the 1100 Series LC to the 1200 Series Rapid Resolution system 4 p
- Agilent Mass-based Fraction Collection Application Note 4 p
- Agilent Using nanospray HPLC-Chip/TOF for routine high sensitivity metabolite identification Application Note 8 p
- Agilent 1200 Series Analysis of Anabolic Agents in Urine by LC/MS/MS 18 p
- Agilent 1200 Series Rapid Resolution LC System Application Note 8 p
- Agilent 1200 Series/6140 LC/MS Continuous Operation Application Note 4 p
- Agilent Technologies Application Note Zhi-xiu Xu Fast high-resolution analysis of notoginseng by rapid resolution liquid 8 p
- Agilent 6140/1200 Series Application Note: Fast Generic LC-MS Method 8 p
- Agilent 1200/6330 LC/MS Application Note: Structure Elucidation of Ginsenosides 8 p
- Agilent 1200 Series ELSD Carbohydrate Analysis Application Note 4 p
- Agilent Determination of Fluvastatin in Plasma Using the Agilent 6410B Triple Quadrupole LC/MS System and Agilent 1200 S 4 p
- Agilent 1200 Series LC Systems Application Note for Radix Bupleuri Analysis with ELSD 8 p
- Agilent 1200 Series Aminoglycoside Antibiotics Analysis Application Note 8 p
- Agilent Metabolite ID Software Application Note 12 p
- Agilent 1200 Series RRLC and 6410B LC/MS Application Note for Impurity D Quantification 8 p
- Agilent 1200 Series RRLC Analysis of Phenolic Antioxidant and Erucamide Slip Additives in Polymer 8 p
- Agilent 1200 Series LC and 6210 TOF MS Application Note 8 p
- Agilent 1200 Series RRLC Application Note for Zuo Jin Pill Quantification 8 p
- Agilent 1200 Series Fast Method Development of Salicylic Acid Process Impurities Application Note 12 p
- Agilent 1200 Series HPLC/UV Melamine Determination Application Note 6 p
- Agilent LC/TOF-MS Rapid Analysis of Crude Fungal Extracts Application Note 8 p
- Agilent Glycopeptide Glycan Analysis of Monoclonal Antibodies Application Note 8 p
- Agilent Application Compendium for Analysis of Pharmaceuticals and Drug Related Impurities 582 p
- Agilent 1200 Series LC System Impurity Profiling Application Note 8 p
- Agilent 1200 Series LC Method Development Solution Application Note 8 p
- Agilent 1200 Series LC System Application Note: Isolation of Impurities with Preparative HPLC 8 p
- Agilent 1200 Series Creating an Optimized Preparative Method Set Application Note 8 p
- Agilent 1200 Series LC System Application Note Part 3 Rapid Condition Scouting 8 p
- Generating nonlinear calibration curve using ChemStation software for analysis of topiramate with Agilent 1200 Series Ev 2 p
- Agilent 5990-3528EN- Running fast LC within USP limits Case study with USP pravastatin sodium chromatographic purity method using the Agilent 1200 Series Rapid Resolution LC system Application Note 8 p
- Agilent Determination of degradation products of Metoprolol tablets with the Agilent 1120 Compact LC after method development with the Agilent 1200 Series Rapid Resolution LC system Application Note 8 p
- Agilent Rapid Method Assessment of Nonsteroidal Anti-Inflammatory Separations using Agilent ZORBAX Rapid Resolution High Throughput Columns with the Agilent 1200 Series Method Development Solution Con 14 p
- Agilent 1200 Series HPLC System Application Note: Analysis of FAME and TG in Biodiesel 4 p
- Agilent 1260 Infinity Analytical SFC System vs 1200 Series LC System UV Detection Comparison 8 p
- Agilent Synthetic Cannabinoids in Oral Fluid Application Note 8 p
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Agilent 1200 Series Isocratic Pump User Manual 124 p
- Agilent 1200 Series Capillary Pump User Manual 178 p
- Agilent 1200 Series VWD/VWD-SL Detector User Manual 130 p
- Agilent 1200 Series Micro Collector/Spotter User Manual 156 p
- Agilent 1200 Series Analytical and Preparative Scale Fraction Collectors User Manual 202 p
- Agilent 1200 Series Sample Capacity Extension User Manual 112 p
- Agilent 1200 Series Dual Loop Autosampler User Guide 142 p
- Agilent 1200 Series Thermostatted Column Compartment G1316A/G1316B/G1316C User Manual 126 p
- Agilent 1200 Series Isocratic Pump User Manual 128 p
- Agilent 1200 Series Vacuum Degasser User Manual 86 p
- Agilent 1200 Series Standard and Preparative Autosamplers User Manual 149 p
- Agilent 1200 Series Autosampler Thermostat User Manual 90 p
- Agilent 1200 Series Preparative Pump User Manual 184 p
- Agilent 1200 Series Capillary Pump User Manual 192 p
- Agilent 1200 Series Micro Vacuum Degasser User Manual 76 p
- Agilent 1200 Series Rapid Resolution LC and Rapid Resolution LC/MS Optimization Guide 133 p
- Agilent 1200 Series Manual Injector User Manual 44 p
- Agilent 1200 Series Quaternary Pump User Manual 150 p
- Agilent 1200 Series Binary Pump SL User Manual 196 p
- Agilent 1200 Series Dual Loop Autosampler User Guide 103 p
- Agilent 1200 Series Column Organizer Manual 4 p
Disassembly, diagnostics and part numbers, for repair.
The shortest path to a working setup, usually only a few pages.
- Agilent 1200 Series Purification Systems
- Agilent Technologies Quantification of 4-Chloroaniline in Chlorhexidine using the Agilent 1200 Series Rapid Resolution LC System coupled with the Agilent 6410 Triple Quadrupole LC/MS System Applicati
- Agilent Impurity Profiling with the Agilent 1200 Series LC System Part 4: Method Validation of a Fast LC Method Application Note
- Agilent 1200 Series Purification System User Manual
- Agilent 1200 Series Handheld Control Module User Guide
Questions answered in these manuals
Is the 1200 Series compatible with third-party detectors?
Yes, the system supports the integration of third-party detectors such as FSA, CAD, and CCIII.
What is the maximum number of columns that can be combined in the method development solution?
Up to eight columns can be combined, provided they have a maximum length of 100 mm.
What is the maximum number of columns that can be connected using two thermostated column ovens and selection valves?
You can connect up to eight columns, provided they are no longer than 100 mm.
What is the maximum sampling rate of the new Agilent Variable Wavelength Detector SL Plus?
The detector offers data acquisition rates of up to 160 Hz.
What is the expected lifespan of the lamps in this system?
The deuterium and xenon lamps are designed with a longevity that exceeds 2000 hours.
What is the maximum data rate of the Agilent 1200 Series DAD SL?
The maximum data rate is 80 Hz, which is needed for peak widths of less than 0.3 s.
From: Agilent 1200 Series Diode-Array Detector SL Technical Note