Key facts
- Brand
- Agilent
- Model
- ZORBAX Eclipse XDB-C8
- Documents
- 7
- Languages
- EN
- Last added
- 2012-07-04
Start here

Agilent ZORBAX Eclipse XDB-C8 RRHT Threaded Column Datasheet
The Agilent ZORBAX Eclipse XDB-C8 RRHT threaded columns are engineered for high-pressure operation up to 600 bar. They utilize eXtra-Dense Bonding (XDB) technology with dimethyl-n-octylsilane ligands bonded to ultra-pure Type B silica support to ensure high efficiency and stability. The packing is doubly endcapped to protect the silica surface from dissolution in mobile phases with intermediate and higher pH levels, making it suitable for separating acidic, basic, and highly polar compounds.
Read onlineAgilent ZORBAX Eclipse XDB-C8 specifications
| Maximum Operating Pressure | 600 bar (9000 psi) |
|---|---|
| Maximum Operating Temperature | 60 °C |
| Optimum pH Range | pH 3-8 |
| Silica Support Surface Area | 180 m²/g |
| Controlled Pore Size | 80A |
Source: Agilent ZORBAX Eclipse XDB-C8 RRHT Threaded Column Datasheet
All Agilent ZORBAX Eclipse XDB-C8 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
- Agilent ZORBAX Eclipse XDB-C8 vs. Symmetry-C8 Stability Test Comparison 2 p
- Agilent ZORBAX Eclipse XDB-C8 Effect of eXtra-Dense Bonding on Peak Shape 2 p
- Agilent ZORBAX Eclipse XDB-C8 Column Lifetime Application Technical Note 2 p
- Agilent ZORBAX Eclipse XDB-C8 HPLC Column Technical Application Note 2 p
Questions answered in these manuals
What is the maximum operating pressure for these columns?
The maximum operating pressure is 600 bar (9000 psi).
From: Agilent ZORBAX Eclipse XDB-C8 RRHT Threaded Column Datasheet
What is the recommended pH range for optimum performance?
Optimum lifetime and performance are obtained at pH 3-8.
From: Agilent ZORBAX Eclipse XDB-C8 RRHT Threaded Column Datasheet
What is the recommended pH range for optimum performance?
Optimum lifetime and performance are obtained at a pH between 3 and 8.
From: Agilent ZORBAX Eclipse XDB-C8 Rapid Resolution Threaded Column Datasheet
Can the column be operated above 600 bar?
No, chromatographic performance has not been tested above this limit.
From: Agilent ZORBAX Eclipse XDB-C8 Rapid Resolution Threaded Column Datasheet
Why is ZORBAX XDB-C8 more stable than Symmetry C8 at higher pH?
ZORBAX particle technology uses a dense silica support that dissolves more slowly at higher pH than the xerogel particles used in Symmetry columns.
From: Agilent ZORBAX Eclipse XDB-C8 vs. Symmetry-C8 Stability Test Comparison
How does extra dense bonding affect chromatographic performance?
The extra dense bonding helps shield the silica support at intermediate pH and decreases the loss of chromatographic performance compared to Symmetry C8.
From: Agilent ZORBAX Eclipse XDB-C8 vs. Symmetry-C8 Stability Test Comparison