Agilent B.03.01 Manuals

ManualLib has 6 documents for the Agilent B.03.01 (Other): 1 other, 2 user manuals, 1 product leaflet, 1 installation guide, 1 quick start guide. Every file can be read online or downloaded as a PDF for free.

Other 1User Manual 2Product Leaflet 1Installation Guide 1Quick Start Guide 1

Key facts

Brand
Agilent
Model
B.03.01
Category
Other
Documents
6
Languages
EN
Last added
2012-07-05

Start here

Agilent 6200 Series TOF 6500 Series Q-TOF LC/MS System Quick Start Guide B.03.01

Agilent 6200 Series TOF 6500 Series Q-TOF LC/MS System Quick Start Guide B.03.01

Quick Start Guide 34 pages · 1.3 MB · EN

Use this guide as a road map for your first steps with the Agilent 6500 Series Q-TOF LC/MS system. It serves as an initial introduction to using the Quadrupole Time-of-Flight mass spectrometer that performs MS/MS using a quadrupole, a hexapole collision cell, and a time-of-flight analyzer.

Read online

Agilent B.03.01 specifications

Processor CompatibilityDual core processor compatible
Minimum RAM512 MB
Operating SystemWindows XP based systems

Source: Agilent ChemStation B.03.01 User Manual for GC, LC, LC/MSD, CE and A/D Systems

All Agilent B.03.01 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What is the default naming format for automatically created sequence folders?

By default, the folder name combines the sequence name with the acquisition date and time.

From: Agilent ChemStation B.02.01/B.03.01 New Concepts of Data Organization Technical Note

How many copies of the method are saved inside each data file?

Each data file contains two copies of the method used to create the run.

From: Agilent ChemStation B.02.01/B.03.01 New Concepts of Data Organization Technical Note

Does this version support UV-Vis or GC/MSD instrumentation?

No, the Agilent ChemStation Revision B.03.01 software release does not relate to UV-Vis or GC/MSD instrumentation; those are controlled by separate products.

From: Agilent ChemStation B.03.01 User Manual for GC, LC, LC/MSD, CE and A/D Systems

What is the minimum RAM required to run this software?

The system requires a minimum of 512 MB RAM.

From: Agilent ChemStation B.03.01 User Manual for GC, LC, LC/MSD, CE and A/D Systems

What chromatographic applications does Agilent ChemStation handle?

The software handles a wide variety of chromatographic applications, such as GC, LC, LC/MS, CE and CE/MS.

From: Agilent ChemStation B.03.01 Feature Overview

What are the PC requirements for running Agilent ChemStation B.03.01?

The system requires Windows XP SP2, a Pentium V processor, 1.5 GHz speed, an SXGA display, 40 GB hard disk, and 512 MB RAM.

From: Agilent ChemStation B.03.01 Feature Overview