Agilent 1200 Series Standard and Preparative Autosamplers User Manual

This manual provides detailed information on the features and usage of the Agilent 1200 Series Standard and Preparative Autosamplers.


Agilent 1200 Series Standard and Preparative Autosamplers User Manual - cover page
Brand
Agilent
Category
Analyzers
Document type
User Manual
Language
English
Pages
149
File format
PDF
File size
3 MB
Published
07 June, 2012
Updated
30 September, 2023
MD5 checksum
C6B95812F5A023E974D4FF5695BD9B0C

About this manual

This manual provides instructions for using Agilent 1200 Series autosamplers, including standard and preparative models. It covers setup, sample handling, performance optimization, maintenance, and troubleshooting. The document includes detailed sections on site requirements, installation procedures, sample trays, injection volumes, and maintenance functions.

The autosamplers are designed for use with Agilent 1200 Series LC systems or compatible systems with remote control. Three models are described: G1329A (standard), G1329B (standard SL), and G2260A (preparative). The document also details cable connections, safety notices, and maintenance kits for each model.

What's inside

  • Introduction to the Autosampler
  • Site Requirements and Specifications
  • Installing the Autosampler
  • Using the Autosampler
  • Optimizing Performance
  • Troubleshooting and Diagnostics
  • Maintenance
  • Parts and Materials for Maintenance
  • Cable Overview
  • Safety and Warranty

Specifications

Injection Volume (Analytical Head)0.1 - 100 µL
Injection Volume (Preparative Head)0.1 - 900 µL
System Pressure Limit (Preparative Head)200 bars or 400 bars
Maximum Pressure (G1329B)600 bar
Sample Rack SizesFull-size (100 x 1.8 ml vials), Half-size (40 x 1.8 ml or 15 x 6 ml vials)

Frequently asked questions

What models are included in the Agilent 1200 Series autosamplers?

Three models are available: G1329A (standard), G1329B (standard SL), and G2260A (preparative).

What is the maximum injection volume for the preparative head?

The preparative head provides injection volumes from 0.1 to 900 µL.

What is the injection volume range for the standard analytical head?

The standard analytical head provides injection volumes from 0.1 to 100 µL.

What are the sample rack options for the autosamplers?

Full-size rack (100 x 1.8 ml vials), half-size rack (40 x 1.8 ml vials), and half-size rack (15 x 6 ml vials).