Analog Devices ADE7858 Manuals

ManualLib has 2 documents for the Analog Devices ADE7858: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
ADE7858
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-03-28

Start here

Analog Devices ADE7858 Energy Metering IC Preliminary Technical Data

Analog Devices ADE7858 Energy Metering IC Preliminary Technical Data

Datasheet 76 pages · 815 KB · EN

The ADE7858 is a poly‑phase multifunction energy‑metering integrated circuit designed for 3‑phase, 3‑ or 4‑wire (delta or wye) power systems. It delivers highly accurate active, reactive and apparent energy data per phase and for the overall system, supporting EN 50470‑1/3 and IEC 62053 standards. The device features flexible serial interfaces (SPI and HSDC), pulse outputs, and built‑in power‑quality measurements such as voltage sag and over‑current detection.

Key specifications include a wide supply voltage range of 2.4 V to 3.7 V, operating temperature from –40 °C to 85 °C, and typical active‑energy measurement error of 0.1 % over a 1000:1 dynamic range. The IC is supplied in a 40‑lead LFCSP lead‑free package and integrates on‑chip reference, ADCs, and a digital signal processor for real‑time calculations.

Read online

Analog Devices ADE7858 specifications

Supply voltage range2.4 V to 3.7 V
Operating temperature-40 °C to 85 °C
Active energy measurement error0.1 % typ (dynamic range 1000:1)
RMS measurement error0.1 % typ (dynamic range 1000:1)
Reference voltage1.2 V (drift 10 ppm/°C typ)
Package type40‑lead LFCSP lead‑free
Clock input frequency16.384 MHz

Source: Analog Devices ADE7858 Energy Metering IC Preliminary Technical Data

All Analog Devices ADE7858 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What supply voltage range does the ADE7858 support?

It operates from 2.4 V up to 3.7 V.

From: Analog Devices ADE7858 Energy Metering IC Preliminary Technical Data

What is the typical accuracy for active energy measurement?

The typical active‑energy measurement error is 0.1 % over a dynamic range of 1000 : 1.

From: Analog Devices ADE7858 Energy Metering IC Preliminary Technical Data

What standards does the ADE78xx family support?

It supports EN 50470‑1, EN 50470‑3, IEC 62053‑21, IEC 62053‑22, and IEC 62053‑23.

From: Analog Devices ADE7854/ADE7858/ADE7868/ADE7878 Handbook

What serial interfaces are available on the ADE7854/ADE7858/ADE7868/ADE7878?

The devices provide SPI, I²C, and a high‑speed data capture (HSDC) serial interface.

From: Analog Devices ADE7854/ADE7858/ADE7868/ADE7878 Handbook