Key facts
- Brand
- Analog Devices
- Model
- ADE7880
- Industry
- Industrial
- Documents
- 5
- Languages
- ZH · EN
- Last added
- 2026-09-29
Start here

Analog Devices UG-356 ADE7880 Evaluation Board User Guide
The document provides a comprehensive overview of the ADE7880 Energy Metering IC evaluation board (UG-356). It details how to connect external transducers for 3-phase energy metering applications, including instructions for using current transformers and Rogowski coils. The guide explains the board's power supply requirements, specifically noting that it requires two domains: one for the microcontroller via USB and another for the isolated ADE7880 components.
Read onlineAnalog Devices ADE7880 specifications
| Supply voltage (VDD) | 3.3 V ±10% |
|---|---|
| Total active‑power measurement error (per phase) | 0.1 % (typical) |
| Bandwidth (‑3 dB) for power measurements | 3.3 kHz |
| Package | 40‑pin LFCSP (lead‑free) |
All Analog Devices ADE7880 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What serial interfaces does the ADE7880 support?
The ADE7880 can communicate via SPI and I²C serial interfaces.
How many pulse outputs are available on the ADE7880?
Three logical pulse outputs (CF1, CF2, CF3) provide various power information.
What standards does the ADE7880 support?
The device supports IEC 62053-21, IEC 62053-22, IEC 62053-23, EN 50470-1, EN 50470-3, and ANSI C12.20 standards.
From: Analog Devices ADE7880 Polyphase Energy Metering IC Datasheet
What is the operating temperature range for the ADE7880?
The IC operates between -40° to +85°C.
From: Analog Devices ADE7880 Polyphase Energy Metering IC Datasheet
What is the silicon status for Version = 1 of the ADE7880?
The silicon status is Rev. A.
From: Analog Devices ADE7880 Polyphase Multifunction Energy Metering IC Anomaly List
Is there a workaround for the high-pass filter issue in phase C voltage data path?
No, there is no workaround available for this specific issue.
From: Analog Devices ADE7880 Polyphase Multifunction Energy Metering IC Anomaly List