Key facts
- Brand
- Analog Devices
- Model
- AD9255
- Category
- Other Electronics
- Documents
- 2
- Languages
- EN
- Last added
- 2012-08-02
Start here

Analog Devices AD9265/AD9255 Evaluation Board User Guide UG-074
The document provides a comprehensive overview of the AD9265/AD9255 Evaluation Board (UG-074), detailing the required equipment, necessary software, and general description of the board's purpose. It explains how to connect the evaluation board with data capture kits and signal sources for characterizing Analog-to-Digital Converters.
Read onlineAnalog Devices AD9255 specifications
| Supported ADC Models | AD9265/AD9255 |
|---|---|
| Analog Input Frequency Range | ~250 MHz |
| Clock Source Options | External, on-board oscillator or AD9517 clocking options |
Source: Analog Devices AD9265/AD9255 Evaluation Board User Guide UG-074
All Analog Devices AD9255 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What software is needed to interface with the devices?
The VisualAnalog SPI controller and SPI control software are required.
From: Analog Devices AD9265/AD9255 Evaluation Board User Guide UG-074
Can the evaluation board be powered by external bench power supplies?
Yes, by removing specific jumpers (P27, P28, P31, P30, P32, and P29) to disconnect the on-board LDOs.
From: Analog Devices AD9265/AD9255 Evaluation Board User Guide UG-074
What is the operating temperature range of the AD9255?
The device is specified for an industrial temperature range of –40 °C to +85 °C.
What output interfaces does the AD9255 provide?
It offers parallel 1.8 V CMOS or LVDS (DDR) output modes.