Analog Devices ADE7768 Manuals

ManualLib has 3 documents for the Analog Devices ADE7768: 2 user manuals, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 1

Key facts

Model
ADE7768
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-03-28

Start here

Analog Devices ADE7768 Energy Metering IC Datasheet

Analog Devices ADE7768 Energy Metering IC Datasheet

Datasheet 20 pages · 302 KB · EN

The ADE7768 is a high‑accuracy energy‑metering integrated circuit that includes an on‑chip oscillator, eliminating the need for an external crystal. It provides positive‑only average real‑power outputs (F1, F2) and a high‑frequency calibration output (CF) for direct drive of electromechanical counters or stepper motors.

The datasheet details electrical specifications, absolute maximum ratings, pin functions, timing characteristics, and typical performance curves, enabling designers to implement the device in low‑cost watt‑hour meters and other metering applications.

Read online

Analog Devices ADE7768 specifications

Supply voltage (Vop)5 V ±5% (4.75 V min – 5.25 V max)
Measurement error (Channel V1)0.1 % reading typ
Phase error (Channel V1)±0.1° max
Oscillator frequency450 kHz nominal
On‑chip reference voltage2.45 V nominal
Package type16‑lead narrow‑body SOIC

Source: Analog Devices ADE7768 Energy Metering IC Datasheet

All Analog Devices ADE7768 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the required supply voltage range for Vop?

Vop must be kept between 4.75 V and 5.25 V (5 V ± 5%).

From: Analog Devices ADE7768 Energy Metering IC Datasheet

How many pins does the ADE7768 have?

The device is supplied in a 16‑lead narrow‑body SOIC package.

From: Analog Devices ADE7768 Energy Metering IC Datasheet

What supply voltage does the ADE7768 require?

The device operates from a single 5 V supply with a tolerance of ±5 %.

From: Analog Devices ADE7768 Energy Metering IC Datasheet

What is the on‑chip reference voltage of the ADE7768?

The on‑chip reference voltage is 2.45 V nominal.

From: Analog Devices ADE7768 Energy Metering IC Datasheet

What supply voltage range does the ADE7768 require?

The device operates with Vop of 5 V ± 5%, which corresponds to a range of 4.75 V to 5.25 V.

From: Analog Devices ADE7768 Datasheet

How does the ADE7768 indicate negative power conditions?

The REVP logic output goes high when negative power is detected, signaling a phase angle greater than 90°.

From: Analog Devices ADE7768 Datasheet