Analog Devices ADE7761A Manuals

ManualLib has 3 documents for the Analog Devices ADE7761A: 2 datasheets, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Datasheet 2User Manual 1

Key facts

Model
ADE7761A
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-05-02

Start here

Analog Devices ADE7761A Energy Metering IC Datasheet

Analog Devices ADE7761A Energy Metering IC Datasheet

Datasheet 24 pages · 512 KB · EN

The ADE7761A is a high‑accuracy, fault‑tolerant energy‑metering integrated circuit designed for 2‑wire distribution systems. It provides active‑power frequency outputs (F1, F2) and a calibration output (CF), supports IEC 62053‑21 accuracy, and includes built‑in fault and missing‑neutral detection.

The document details the functional block diagram, pin configuration, electrical specifications, timing characteristics, and application notes for interfacing the device to a microcontroller. It also covers performance limits, ESD precautions, and typical performance curves.

Read online

Analog Devices ADE7761A specifications

Supply voltage (VDD)5 V ± 5%
Operating temperature range-40°C to +85°C
Phase error between channels (capacitive)±0.05° (0.8° max)
Maximum differential input voltage±660 mV peak
Logic output high voltage≥4 V
Power‑supply rejection (frequency variation)0.01 % typ

Source: Analog Devices ADE7761A Energy Metering IC Datasheet

All Analog Devices ADE7761A documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What supply voltage does the ADE7761A require?

The device operates from a single 5 V supply with a tolerance of ±5 %.

From: Analog Devices ADE7761A Energy Metering IC Datasheet

How does the ADE7761A detect a missing neutral condition?

It continuously monitors the input voltage; when no voltage is present, the FAULT pin goes high and the device continues billing using the active current signal.

From: Analog Devices ADE7761A Energy Metering IC Datasheet

What is the fault detection threshold?

A fault is indicated when the phase and neutral currents differ by more than 6.25 % of the larger current.

From: Analog Devices ADE7761A Energy Metering IC Datasheet

What is the missing‑neutral detection threshold?

Missing neutral is detected when the voltage difference between the input and neutral is less than 59.4 mV peak.

From: Analog Devices ADE7761A Energy Metering IC Datasheet

How does the ADE7761A detect a missing neutral condition?

It continuously monitors the input voltage; when no voltage is present, the FAULT pin goes high and billing continues based on the active current signal.

From: Analog Devices ADE7761A Datasheet

What supply voltage is required for the ADE7761A?

The device operates from a single 5 V supply with a tolerance of ±5 %.

From: Analog Devices ADE7761A Datasheet