Analog Devices ADE7763 Manuals

ManualLib has 5 documents for the Analog Devices ADE7763: 3 user manuals, 2 datasheets. Every file can be read online or downloaded as a PDF for free.

User Manual 3Datasheet 2

Key facts

Model
ADE7763
Industry
Industrial
Documents
5
Languages
EN
Last added
2012-08-02

Start here

Analog Devices ADE7763 Single-Phase Energy Metering IC Datasheet

Analog Devices ADE7763 Single-Phase Energy Metering IC Datasheet

Datasheet 56 pages · 866 KB · EN

The ADE7763 is a single-phase active and apparent energy metering IC designed for high accuracy over large variations in environmental conditions. It incorporates two second-order, 16-bit U-A ADCs, a digital integrator on Channel 1, reference circuitry, a temperature sensor, and all signal processing required for active and apparent energy measurements, line-voltage period measurements, and RMS calculations on voltage and current channels.

The device supports direct interface to current sensors with di/dt output via an on-chip digital integrator, as well as shunts and current transformers via an APGA input. It provides a serial interface to read data and a pulse output frequency proportional to active power. Various system calibration features ensure high accuracy, and the part detects short-duration low or high voltage variations. The ADE7763 is available in a 20-lead SSOP package.

Read online

Analog Devices ADE7763 specifications

Active Power Measurement Error0.1% typ
Active Power Measurement Bandwidth14 kHz
Phase Error between Channels+0.05 max
Supply Current AIDD3 mA max
On-Chip Reference Voltage2.4 V
Input Clock Frequency1 MHz to 4 MHz
Package Type20-lead SSOP

Source: Analog Devices ADE7763 Single-Phase Energy Metering IC Datasheet

All Analog Devices ADE7763 documents by type

Questions answered in these manuals

What is the active power measurement error?

The active power measurement error is 0.1% typical over a dynamic range of 1000 to 1.

From: Analog Devices ADE7763 Single-Phase Energy Metering IC Datasheet

Does the ADE7763 support direct interface to di/dt current sensors?

Yes, the on-chip digital integrator enables direct interface to current sensors with di/dt output.

From: Analog Devices ADE7763 Single-Phase Energy Metering IC Datasheet

What is the clock frequency for specified performance?

The CLKIN frequency must be 3.579545 MHz.

From: Analog Devices ADE7763 Single-Phase Active and Apparent Energy Metering IC Datasheet

What is the nominal voltage of the on-chip reference?

The on-chip reference has a nominal voltage of 2.4 V.

From: Analog Devices ADE7763 Single-Phase Active and Apparent Energy Metering IC Datasheet

What is the absolute maximum rating for AVDD relative to AGND?

AVDD may be as low as –0.3 V and as high as +7 V relative to AGND.

From: Analog Devices ADE7763 Single-Phase Active and Apparent Energy Metering IC Datasheet

How does the ZX pin indicate zero‑crossing?

The ZX output toggles logic high and low at the zero‑crossing of the differential signal on Channel 2.

From: Analog Devices ADE7763 Single-Phase Active and Apparent Energy Metering IC Datasheet