Analog Devices ADE7816 Manuals

ManualLib has 4 documents for the Analog Devices ADE7816: 1 datasheet, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Datasheet 1User Manual 1

Key facts

Model
ADE7816
Industry
Industrial
Documents
4
Languages
EN
Last added
2012-08-02

Start here

ANALOG DEVICES UG-370 handbook

ANALOG DEVICES UG-370 handbook

User Manual 16 pages · 1.4 MB · EN

The document provides instructions for using the ADE7816 Evaluation Kit, which includes an evaluation board and PC-based LabVIEW software. The kit allows users to evaluate the performance of the ADE7816 6-channel energy measurement IC by connecting it to a PC via USB.

The guide covers hardware configuration details such as powering the board with an external 3.3V supply, configuring jumpers for different sensor types (current transformers or Rogowski coils), and setting up typical input configurations for voltage and current channels.

Read online

Analog Devices ADE7816 specifications

Number of current input channels6
Number of voltage input channels1
Active and reactive energy measurement errorLess than 0.1%
Dynamic range1000:1
Supply voltage3.3 V
Package type40-lead LFCSP
Voltage reference drift10 ppm/°C
Bandwidth operation2kHz

Source: Analog Devices ADE7816 Multichannel Energy Measurement IC Datasheet

All Analog Devices ADE7816 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What types of sensors does the ADE7816 support?

The device supports current transformers and Rogowski coil input sensors.

From: Analog Devices ADE7816 Multichannel Energy Measurement IC Datasheet

What interfaces does the ADE7816 provide?

It provides access via SPI, I2C, and a dedicated high speed data capture (HSDC) port.

From: Analog Devices ADE7816 Multichannel Energy Measurement IC Datasheet

When is phase calibration required?

Phase calibration is required when using a sensor that introduces a phase delay.

From: Analog Devices AN-1152 Calibrating ADE7816 Application Note

What is the recommended power factor for gain and phase calibration?

The power factor should be set to around 0.5.

From: Analog Devices AN-1152 Calibrating ADE7816 Application Note

What is the maximum error for active energy measurement over a dynamic range of 1000 to 1?

The active energy measurement error is less than 0.1% over a dynamic range of 1000 to 1.

From: Analog Devices ADE7816 Energy Metering IC Datasheet

What is the operating bandwidth of the device?

The device supports 2 kHz bandwidth operation.

From: Analog Devices ADE7816 Energy Metering IC Datasheet