Key facts
- Brand
- Analog Devices
- Model
- ADE7816
- Industry
- Industrial
- Documents
- 4
- Languages
- EN
- Last added
- 2012-08-02
Start here

ANALOG DEVICES UG-370 handbook
The document provides instructions for using the ADE7816 Evaluation Kit, which includes an evaluation board and PC-based LabVIEW software. The kit allows users to evaluate the performance of the ADE7816 6-channel energy measurement IC by connecting it to a PC via USB.
The guide covers hardware configuration details such as powering the board with an external 3.3V supply, configuring jumpers for different sensor types (current transformers or Rogowski coils), and setting up typical input configurations for voltage and current channels.
Analog Devices ADE7816 specifications
| Number of current input channels | 6 |
|---|---|
| Number of voltage input channels | 1 |
| Active and reactive energy measurement error | Less than 0.1% |
| Dynamic range | 1000:1 |
| Supply voltage | 3.3 V |
| Package type | 40-lead LFCSP |
| Voltage reference drift | 10 ppm/°C |
| Bandwidth operation | 2kHz |
Source: Analog Devices ADE7816 Multichannel Energy Measurement IC Datasheet
All Analog Devices ADE7816 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What types of sensors does the ADE7816 support?
The device supports current transformers and Rogowski coil input sensors.
From: Analog Devices ADE7816 Multichannel Energy Measurement IC Datasheet
What interfaces does the ADE7816 provide?
It provides access via SPI, I2C, and a dedicated high speed data capture (HSDC) port.
From: Analog Devices ADE7816 Multichannel Energy Measurement IC Datasheet
When is phase calibration required?
Phase calibration is required when using a sensor that introduces a phase delay.
From: Analog Devices AN-1152 Calibrating ADE7816 Application Note
What is the recommended power factor for gain and phase calibration?
The power factor should be set to around 0.5.
From: Analog Devices AN-1152 Calibrating ADE7816 Application Note
What is the maximum error for active energy measurement over a dynamic range of 1000 to 1?
The active energy measurement error is less than 0.1% over a dynamic range of 1000 to 1.
What is the operating bandwidth of the device?
The device supports 2 kHz bandwidth operation.