Analog Devices AN-1152 Calibrating ADE7816 Application Note

This application note describes how to calibrate the ADE7816. It details the calibration procedure, including equations and examples of how to calculate each constant. The ADE7816 is a high accuracy multichannel metering IC that allows the energy to be measured on up to six current channels. It provides a variety of energy measurements including active and reactive energy, along with current and voltage rms readings. A variety of power quality features, including no load, reverse power, and angle measurement, are also provided. The ADE7816 can be accessed via an SPI, I2C, or high speed data capture (HSDC) interface.


Analog Devices AN-1152 Calibrating ADE7816 Application Note - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Application Note
Language
English
Pages
12
File format
PDF
File size
164 KB
Published
02 August, 2012
Updated
29 September, 2023
Model
ADE7816
MD5 checksum
7799F6EF17B952548A18F5089152B2B6

About this manual

This document details how to calibrate the ADE7816, a high accuracy multichannel metering IC capable of measuring energy on up to six current channels. It provides a variety of energy measurements including active and reactive energy, along with current and voltage rms readings.

The note outlines a three-stage calibration process: gain, phase, and offset. It explains the required register settings, input conditions, and specific equations for calculating constants such as Wh/LSB and gain adjustments for current channels to ensure accurate readings.

What's inside

  • Introduction
  • Calibration Basics
  • Calibration Steps
  • Calibration Setup
  • Required Register Settings
  • Energy Calibration
  • Current Channel Gain Matching
  • Phase Calibration

Specifications

Number of current channelssix
Calibration stagesgain, phase, and offset

Frequently asked questions

When is phase calibration required?

Phase calibration is required when using a sensor that introduces a phase delay.

What is the recommended power factor for gain and phase calibration?

The power factor should be set to around 0.5.

How many calibration stages are typically required?

A maximum of three calibration stages is required: gain, phase, and offset.