Analog Devices AD9642 Manuals

ManualLib has 3 documents for the Analog Devices AD9642: 1 datasheet, 1 user manual, 1 quick start guide. Every file can be read online or downloaded as a PDF for free.

Datasheet 1User Manual 1Quick Start Guide 1

Key facts

Model
AD9642
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-08-02

Start here

Analog Devices AD9642 Evaluation Board Quick Start Guide

Analog Devices AD9642 Evaluation Board Quick Start Guide

Quick Start Guide 4 pages · 189 KB · EN

This document serves as a quick start guide for evaluating the AD9642 high-speed analog-to-digital converter (ADC) using the HSC-ADC-EVALCZ capture board. It details the necessary equipment, including power supplies and signal generators, and outlines the physical connections between the evaluation boards and the PC via USB.

Read online

Analog Devices AD9642 specifications

Operating Voltage (Wall Outlet)100 V ac to 240 V ac at 47 Hz to 63 Hz
Power Supply Output6 V, 2.5 A maximum
Analog Input Impedance50 Ω
Nominal Input Drive Level10 dBm (2 V p-p full scale)
Clock Input Impedance50 Ω terminated

Source: Analog Devices AD9642/AD9634/AD6672 Evaluation Board User Guide UG-386

All Analog Devices AD9642 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What is the required input clock level for the AD9642?

The input clock level should be between 10dBm and 14dBm.

From: Analog Devices AD9642 Evaluation Board Quick Start Guide

What is the recommended signal generator level for testing?

For best results, the generator level should be set to 8dBm to 12dBm.

From: Analog Devices AD9642 Evaluation Board Quick Start Guide

What software interfaces are provided with the evaluation board?

The board includes VisualAnalog and SPI controller software interfaces for setup and control.

From: Analog Devices AD9642/AD9634/AD6672 Evaluation Board User Guide UG-386

Can the evaluation board use an external clock source?

Yes, the board is set by default to use an external clock generator connected to J506.

From: Analog Devices AD9642/AD9634/AD6672 Evaluation Board User Guide UG-386

What is the maximum sampling rate of the AD9642?

The AD9642 can sample at up to 250 MSPS.

From: Analog Devices AD9642 Datasheet

What supply voltage does the AD9642 require?

It requires a 1.8 V analog supply (AVDD) and a 1.8 V digital output driver supply (DRVDD).

From: Analog Devices AD9642 Datasheet