Analog Devices AD9642/AD9634/AD6672 Evaluation Board User Guide UG-386
The document is a User Guide (UG-386) for the AD9642/AD9634/AD6672 evaluation board. It details the support circuitry required to operate these high-speed Analog-to-Digital Converters in various modes and configurations, including power supply options, input signal requirements, and clocking setups.
The guide covers default operation settings, jumper selection for configuring analog inputs (balun or amplifier), and clock circuits (transformer-coupled or AD9523). It also describes the necessary equipment, software interfaces like VisualAnalog and SPI controller, and provides quick start procedures for testing.
Analog Devices AD9634 specifications
| Operating Voltage (Wall Outlet) | 100 V ac to 240 V ac at 47 Hz to 63 Hz |
|---|---|
| Power Supply Output | 6 V, 2.5 A maximum |
| Analog Input Impedance | 50 Ω |
| Nominal Input Drive Level | 10 dBm (2 V p-p full scale) |
| Clock Input Impedance | 50 Ω terminated |
Source: Analog Devices AD9642/AD9634/AD6672 Evaluation Board User Guide UG-386
All Analog Devices AD9634 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What software interfaces are provided with the evaluation board?
The board includes VisualAnalog and SPI controller software interfaces for setup and control.
From: Analog Devices AD9642/AD9634/AD6672 Evaluation Board User Guide UG-386
Can the evaluation board use an external clock source?
Yes, the board is set by default to use an external clock generator connected to J506.
From: Analog Devices AD9642/AD9634/AD6672 Evaluation Board User Guide UG-386
What is the maximum sampling rate of the AD9634?
The AD9634 can sample at up to 250 MSPS.
Does the AD9634 support power‑down modes?
Yes, it includes energy‑saving power‑down modes.