Analog Devices AD7400A Manuals

ManualLib has 3 documents for the Analog Devices AD7400A: 2 user manuals, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 1

Key facts

Model
AD7400A
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-08-02

Start here

User ManualANALOG DEVICES Using the AD7400A Isolated Modulator as an Isolated Amplifier Manual

ANALOG DEVICES Using the AD7400A Isolated Modulator as an Isolated Amplifier Manual

User Manual

This document describes how to convert the AD7400A into an isolated amplifier using a simple RC filter or more sophisticated active filters. The AD7400A is an isolated ΣΔ modulator typically used to measure current or monitor DC bus voltage in motor drives.

Read online

Analog Devices AD7400A specifications

Clock Rate10 MHz
Resolution16 bits
Input Voltage Range±250 mV (full scale ±320 mV)
Operating Temperature‑40 °C to +125 °C
Isolation Voltage5000 Vrms (1 min, UL 1577)
Power Consumption15.5 mA typical at 5.5 V

Source: Analog Devices AD7400A Datasheet Rev C

All Analog Devices AD7400A documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the clock frequency of the AD7400A?

The device operates with a 10 MHz master clock output.

From: Analog Devices AD7400A Datasheet Rev C

What isolation voltage does the AD7400A meet under UL standards?

It is rated for 5000 Vrms isolation for 1 minute according to UL 1577.

From: Analog Devices AD7400A Datasheet Rev C

What is the input voltage range of the AD7400A?

The AD7400A accepts a differential input range of ±250 mV (full‑scale +320 mV).

From: Analog Devices AD7400A Datasheet

How much power does the AD7400A consume in typical operation?

Typical power consumption is 15.5 mA when powered at 5.5 V.

From: Analog Devices AD7400A Datasheet