Analog Devices ADE7760 Manuals

ManualLib has 3 documents for the Analog Devices ADE7760: 3 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 3

Key facts

Model
ADE7760
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-08-02

Start here

DatasheetANALOG DEVICES ADE7760 handbook(1)

ANALOG DEVICES ADE7760 handbook(1)

Datasheet

ADE7760 is a high accuracy energy measurement IC that supports IEC 687/61036 standard, dynamic range of 500:1, error less than 0.1%, frequency output terminal F1 and F2 can output active power, high frequency output terminal CF is used for calibration, can output instantaneous active power, in the two-wire distribution system, continuous monitoring of phase current and neutral current can realize fault detection, current channel input level is best suited for current transformer sensors, in fault state, larger current (phase current or neutral current) is used for billing, two logic outputs (FAULT and REVP) can be used to indicate potential wiring errors or fault conditions, can directly drive electromechanical counters and two-phase stepper motors (F1 and F2), proprietary ADC and DSP can provide high precision oversampling measurement.

Read online

Analog Devices ADE7760 specifications

Measurement Error0.1 % of reading (typ)
Output Frequency Variation0.01 % (typ)
Maximum Differential Input Signal+660 mV peak
Oscillator Frequency450 kHz
Supply Voltage (Vop)5 V ±5 %
Temperature Coefficient (Reference)30 ppm/°C (typ)

Source: Analog Devices ADE7760 Energy Metering IC Handbook

All Analog Devices ADE7760 documents by type

Datasheet 3

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the measurement error of the ADE7760?

The ADE7760 has a measurement error of 0.1 % of reading, typical, over a dynamic range of 500 to 1.

From: Analog Devices ADE7760 Energy Metering IC Handbook

How does the ADE7760 detect faults?

It continuously monitors phase and neutral currents and signals a fault when the currents differ by more than 6.25 %.

From: Analog Devices ADE7760 Energy Metering IC Handbook

What supply voltage is required for the ADE7760?

The ADE7760 operates from a single 5 V supply with a tolerance of ±5 %.

From: Analog Devices ADE7760 Energy Metering IC Handbook

How does the ADE7760 indicate a fault condition?

It provides two logic outputs, FAULT and REVP, which can be used to signal a potential mis‑wiring or fault condition.

From: Analog Devices ADE7760 Energy Metering IC Handbook