Key facts
- Brand
- Analog Devices
- Model
- AD1837
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2012-08-02
Start here

Silicon Anomaly Sheet AD1837 Audio Codec
The Silicon Anomaly Sheet for the AD1837 describes specific bugs present in this version of the part, noting that these issues have been fixed in the AD1837A revision. The document focuses on known anomalies related to ADC and DAC operations.
Key sections cover an ADC Phase Shift Bug occurring during data transfers or register programming, a phase shift issue in TDM256 Master Mode where no workaround is possible at the hardware level, and rare write failures for DAC registers. For each identified bug, the text provides specific circuit diagrams or software procedures to ensure proper operation.
Analog Devices AD1837 specifications
| ADC Resolution | 24 Bits |
|---|---|
| DAC Resolution | 24 Bits |
| Supply Voltage (AVDD, DVDD) | 5.0 V |
| Operating Temperature Range | -40 C to +85 C |
| Package Type | 52-Lead MQFP |
All Analog Devices AD1837 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What is the recommended workaround for the ADC Phase Shift Bug?
Synchronize the rising edge of PD/RST with the appropriate LRCLK or FSTDM signal to ensure updates occur in a safe region.
Can the phase shift error be fixed when operating in TDM256 Master Mode?
No, because the FSTDM signal is generated after reset and cannot be synchronized; reestablishing the phase relationship must be done via software control.
What are the supported sample rates?
The device supports up to 96 kHz sample rates on all channels, with a 192 kHz rate available on one DAC.
What is the dynamic range of the ADC?
The ADC offers a dynamic range of 105 dB with A-Weighted filtering.
What is the recommended workaround for the ADC Phase Shift Bug?
Synchronize the rising edge of PD/RST with the appropriate LRCLK or FSTDM edge to ensure safe result updates.
How should registers be programmed during 96 kHz operation to avoid errors?
Programming the IMCLK divider and ADC sample rate registers must occur during the internal reset time.