Analog Devices AN-950 ADE71xx/ADE75xx Meter Calibration Guide
This application note describes the calibration procedures for ADE71xx/ADE75xx series single-phase energy meters. The first part details the calculation of constants required for active power, RMS current/voltage, apparent power, and reactive power calibration, including examples using a reference meter or precise source.
The second part outlines how to use LabVIEW™ calibration software designed specifically for interaction with ADE71xx/ADE75xx reference designs. It covers determining the isolated COM port, downloading firmware, accessing EEPROM calibration constants, and performing power and RMS calibrations via the software interface.
Analog Devices ADE75xx specifications
| Dynamic Range (Active Energy) | less than 0.1% error over a dynamic range of 500 to 1 at 25°C |
|---|---|
| Power Consumption (Single-Phase) | as low as 15 mW (typ) |
| Power Consumption (Polyphase) | 30 mW (typ) |
| Supply Voltage | Single 5 V supply |
| LCD Segments | 104-segment LCD driver |
| Temperature Drift (Reference) | 20 ppm to 30 ppm typ |
Source: Analog Devices ADE71xx/ADE75xx Energy Meter Product Family Overview
All Analog Devices ADE75xx documents by type
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What is the purpose of the calibration procedure described in this guide?
The guide explains how to calibrate ADE71xx/ADE75xx meters to remove differences caused by external components or internal reference voltage sources.
From: Analog Devices AN-950 ADE71xx/ADE75xx Meter Calibration Guide
What specific input conditions are used in the example for calculating the expected CF output frequency?
The example calculates the frequency based on a load of 220 V and 10 A with a power factor of 1.
From: Analog Devices AN-950 ADE71xx/ADE75xx Meter Calibration Guide
What is the life expectancy of ADE products?
Based on HTOL tests, meter replacement is only needed every 60 years if other components have similar life expectancy.
From: Analog Devices ADE71xx/ADE75xx Energy Meter Product Family Overview
Does the ADE family include an MCU core?
Yes, it includes an 8052 MCU core with flash memory.
From: Analog Devices ADE71xx/ADE75xx Energy Meter Product Family Overview