Agilent 1200 Series HPLC Manuals

ManualLib has 4 documents for the Agilent 1200 Series HPLC: 4 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 4

Key facts

Brand
Agilent
Model
1200 Series HPLC
Documents
4
Languages
EN
Last added
2012-07-02

Start here

Agilent Antibody Analysis by ESI-TOF LC/MS Application Note

Agilent Antibody Analysis by ESI-TOF LC/MS Application Note

Application Note 12 pages · 1.5 MB · EN

Monoclonal antibodies (mAbs) are complex structures requiring accurate characterization, particularly for determining molecular weight. Traditional methods like gel analysis or MALDI-TOF often suffer from imprecision or lengthy processing times.

This study evaluates the combination of Agilent Technologies Poroshell column, 1200 HPLC system, and 6210 Time-of-Flight mass spectrometer for analyzing intact IgG4 antibodies. The method achieves a short retention time of 2.78 minutes with good chromatographic peak shape. Mass spectral analysis successfully resolved various antibody subpopulations, demonstrating routine mass accuracy better than 25 ppm.

Read online

Agilent 1200 Series HPLC specifications

Retention time for intact IgG42.78 min
Routine mass accuracybetter than 25 ppm
Total analysis time9-minute
HPLC flow rate~500 l/min
Column oven temperature90°C
Capillary voltage (TOF MS)5500 V
Drying gas temperature300°C

Source: Agilent Antibody Analysis by ESI-TOF LC/MS Application Note

All Agilent 1200 Series HPLC documents by type

Questions answered in these manuals

What is the routine mass accuracy demonstrated by the system?

The routine mass accuracy demonstrated by the TOF MS was better than 25 ppm.

From: Agilent Antibody Analysis by ESI-TOF LC/MS Application Note

Which column is used for the optimal chromatographic peak shape?

The Poroshell C8 column was used, resulting in very good chromatographic peak shape.

From: Agilent Antibody Analysis by ESI-TOF LC/MS Application Note

What is the limit of detection for melamine in this method?

The limit of detection is 10 pg/kg.

From: Agilent 1200 Series HPLC/UV Melamine Determination Application Note

What is the linear calibration range for melamine?

Linear calibration curves were obtained over the range of 1 to 20 mg/kg.

From: Agilent 1200 Series HPLC/UV Melamine Determination Application Note

Which detector is used for this analysis?

A refractive index detector (RID) is used.

From: Agilent 1200 Series HPLC System Application Note: Analysis of FAME and TG in Biodiesel

What is the quantification limit for triglyceride analysis using this system?

The system can detect small amounts of triglyceride with a quantification limit of 1 g/10 pL.

From: Agilent 1200 Series HPLC System Application Note: Analysis of FAME and TG in Biodiesel