Agilent 500 Ion Trap Manuals

ManualLib has 19 documents for the Agilent 500 Ion Trap (Other): 7 product leaflets, 1 datasheet, 7 application notes, 1 quick start guide. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 7Datasheet 1Application Note 7Quick Start Guide 1

Key facts

Brand
Agilent
Model
500 Ion Trap
Category
Other
Documents
19
Languages
EN
Last added
2012-07-05

Start here

Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series Quick Start Guide

Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series Quick Start Guide

Quick Start Guide 12 pages · 749 KB · EN

This document serves as a quick start guide for integrating the Agilent 1200 Infinity Series Liquid Chromatography system with the Agilent 500 Ion Trap LC/MS mass spectrometer. It outlines the workflow for setting up the systems to automatically inject samples using MS Workstation and ChemStation software.

Read online

Agilent 500 Ion Trap specifications

Mass Range100-2000 Da
Signal-to-Noise Ratio167:1
Sensitivity Improvementeight times greater

Source: Agilent 500 Ion Trap LC/MS High Mass Sensitivity Technical Overview

All Agilent 500 Ion Trap documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What evidence is provided regarding long-term contamination?

One thousand consecutive injections showed no indication of contamination or changes in system sensitivity.

From: Agilent 500 Ion Trap LC/MS Atmospheric Pressure Ionization Interface Technical Overview

What is the Agilent 500 Ion Trap LC/MS Atmospheric Pressure Ionization Interface designed to do?

It is designed to meet the challenge of routine analysis of large numbers of samples in a dirty matrix.

From: Agilent 500 Ion Trap LC/MS Atmospheric Pressure Ionization Interface Technical Overview

What is the primary benefit of the Enhanced Charge Capacity (ECC) feature in the Agilent 500 Ion Trap LC/MS?

The Enhanced Charge Capacity allows the instrument to reliably detect trace amounts of analytes even when they are present in a high concentration of coeluting analytes within heavy matrices.

From: Agilent 500 Ion Trap LC/MS Technical Overview

How much can the ion time be increased on the Agilent 500 Ion Trap before mass resolution is noticeably degraded?

The Agilent 500 Ion Trap can tolerate a 100-fold increase in the ion time with little noticeable decrease in mass resolution.

From: Agilent 500 Ion Trap LC/MS Technical Overview

What is SelecTemp?

SelecTemp is a temperature-programmable atmospheric pressure ionization dry gas control feature of the Agilent 500 Ion Trap LC/MS.

From: Agilent 500 Ion Trap LC/MS SelecTemp Technical Overview

How does SelecTemp improve sensitivity for thermally labile compounds?

It provides a factor of three improvement in signal-to-noise by lowering the drying gas temperature from 330 °C to 300 °C during the run.

From: Agilent 500 Ion Trap LC/MS SelecTemp Technical Overview