Key facts
Start here

Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series Quick Start Guide
This document serves as a quick start guide for integrating the Agilent 1200 Infinity Series Liquid Chromatography system with the Agilent 500 Ion Trap LC/MS mass spectrometer. It outlines the workflow for setting up the systems to automatically inject samples using MS Workstation and ChemStation software.
Read onlineAgilent 500 Ion Trap specifications
| Mass Range | 100-2000 Da |
|---|---|
| Signal-to-Noise Ratio | 167:1 |
| Sensitivity Improvement | eight times greater |
Source: Agilent 500 Ion Trap LC/MS High Mass Sensitivity Technical Overview
All Agilent 500 Ion Trap documents by type
- Agilent 500 Ion Trap LC/MS Atmospheric Pressure Ionization Interface Technical Overview 4 p
- Agilent 500 Ion Trap LC/MS Technical Overview 6 p
- Agilent 500 Ion Trap LC/MS SelecTemp Technical Overview 4 p
- Agilent 500 Ion Trap LC/MS System Fast Polarity Switching Technical Overview 4 p
- Agilent 500 Ion Trap LC/MS High Mass Sensitivity Technical Overview 4 p
- Agilent 500 Ion Trap LC/MS Ion Optics Technical Overview 4 p
- Agilent 500 Ion Trap LC/MS Product Brochure 12 p
Ratings, dimensions and ordering codes, for selection and design work.
How to use the product for one specific task, with worked examples.
- Agilent 500 Ion Trap LC/MS with TurboDDS Application Note 8 p
- Agilent 500 Ion Trap LC/MS Aflatoxin Identification Application Note 4 p
- Agilent 500 Ion Trap LC/MS Application Note: Determination of Opiates and Other Drugs of Abuse 4 p
- Agilent 500 Ion Trap LC/MS Application Note for EPA 535 4 p
- Agilent Data Acquisition Analysis of 7-ethoxycoumarin its Metabolites Using TurboDDS Software in the Agilent 500 Ion Trap LC/MS 6 p
- Agilent 500 Ion Trap LC/MS Application Note for Morphine Detection 6 p
- Agilent 500 Ion Trap MS and 385-ELSD Application Note for Pharmaceutical Analysis 8 p
The shortest path to a working setup, usually only a few pages.
Questions answered in these manuals
What evidence is provided regarding long-term contamination?
One thousand consecutive injections showed no indication of contamination or changes in system sensitivity.
From: Agilent 500 Ion Trap LC/MS Atmospheric Pressure Ionization Interface Technical Overview
What is the Agilent 500 Ion Trap LC/MS Atmospheric Pressure Ionization Interface designed to do?
It is designed to meet the challenge of routine analysis of large numbers of samples in a dirty matrix.
From: Agilent 500 Ion Trap LC/MS Atmospheric Pressure Ionization Interface Technical Overview
What is the primary benefit of the Enhanced Charge Capacity (ECC) feature in the Agilent 500 Ion Trap LC/MS?
The Enhanced Charge Capacity allows the instrument to reliably detect trace amounts of analytes even when they are present in a high concentration of coeluting analytes within heavy matrices.
How much can the ion time be increased on the Agilent 500 Ion Trap before mass resolution is noticeably degraded?
The Agilent 500 Ion Trap can tolerate a 100-fold increase in the ion time with little noticeable decrease in mass resolution.
What is SelecTemp?
SelecTemp is a temperature-programmable atmospheric pressure ionization dry gas control feature of the Agilent 500 Ion Trap LC/MS.
From: Agilent 500 Ion Trap LC/MS SelecTemp Technical Overview
How does SelecTemp improve sensitivity for thermally labile compounds?
It provides a factor of three improvement in signal-to-noise by lowering the drying gas temperature from 330 °C to 300 °C during the run.
From: Agilent 500 Ion Trap LC/MS SelecTemp Technical Overview