Agilent 1120 Manuals

ManualLib has 25 documents for the Agilent 1120 (Other): 2 product leaflets, 21 application notes, 1 installation guide. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 2Application Note 21Installation Guide 1

Key facts

Brand
Agilent
Model
Agilent 1120
Category
Other
Documents
25
Languages
JA · EN
Last added
2012-07-09

Start here

Agilent 1120 Compact LC HPLC Product Brochure

Agilent 1120 Compact LC HPLC Product Brochure

Product Leaflet 8 pages · 755 KB · JA

The Agilent 1120 Compact LC is a compact high-performance liquid chromatography (HPLC) system designed to provide precise analysis capabilities. It supports multiple detection modes, including UV-Vis, and is suitable for applications such as drug analysis, environmental monitoring, and food testing. This manual is written in Japanese.

Read online

Agilent 1120 specifications

Delay volumeapproximately 850 pL
Injection volume range0.1 up to 100 pL
Coefficient of correlation0.999998

Source: Agilent 1120 Compact LC Performance Characteristics

All Agilent 1120 documents by type

Application Note 21

How to use the product for one specific task, with worked examples.

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

What is the maximum flow rate the Agilent 1120 Compact LC can handle?

The instrument can handle a maximum flow rate of 10 mL/min.

From: Agilent 1120 Compact LC HPLC Product Brochure

What is the detection limit for the UV-Vis detector in the Agilent 1120 Compact LC?

The detection limit is 100 pg.

From: Agilent 1120 Compact LC HPLC Product Brochure

What is the concentration of Related Compound A in the system suitability test sample?

The concentration of Related Compound A in the system suitability test sample was set to 0.001 mg/mL.

From: Agilent 1120 Compact LC Application Note for Pravastatin Sodium USP Purity Analysis

What is the relative standard deviation (RSD) for peak area of the standard sample?

The RSD value obtained was 0.3%.

From: Agilent 1120 Compact LC Application Note for Pravastatin Sodium USP Purity Analysis

What is the delay volume of the Agilent 1120 Compact LC?

The delay volume is approximately 850 pL.

From: Agilent 1120 Compact LC Performance Characteristics

What is the injection volume range for the autosampler?

The autosampler supports an injection volume range from 0.1 up to 100 pL without hardware modification.

From: Agilent 1120 Compact LC Performance Characteristics