Agilent 6520 Q-TOF Manuals

ManualLib has 4 documents for the Agilent 6520 Q-TOF: 4 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 4

Key facts

Brand
Agilent
Model
6520 Q-TOF
Documents
4
Languages
EN
Last added
2012-07-02

Start here

Agilent 6520 QTOF LC/MS System Metabolite Identification Application Note

Agilent 6520 QTOF LC/MS System Metabolite Identification Application Note

Application Note 8 pages · 1.4 MB · EN

This document details the identification of pharmaceutical metabolites during drug discovery and development. It highlights the benefits of using the Agilent 6520 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF) LC/MS system combined with Agilent MassHunter Metabolite Identification (MetID) software.

Read online

Agilent 6520 Q-TOF specifications

System ModelAgilent 6520 Accurate-Mass O-TOF LC/MS system
SoftwareAgilent MassHunter Metabolite Identification software
ColumnZORBAX SB-C18 column, 2.1 x 150 mm, 1.8 pm
Flow rate0.5 mL/min
Mass range100-1000
Collision energy35 V

Source: Agilent 6520 QTOF LC/MS System Metabolite Identification Application Note

All Agilent 6520 Q-TOF documents by type

Questions answered in these manuals

What is the purpose of this application note?

It describes the identification of pharmaceutical metabolites using the Agilent 6520 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF) LC/MS system and Agilent MassHunter Metabolite Identification (MetID) software.

From: Agilent 6520 QTOF LC/MS System Metabolite Identification Application Note

How is high mass resolution utilized?

High mass resolution is used to elucidate the structures of metabolites by differentiating between fragments of isobaric mass in MS/MS spectra.

From: Agilent 6520 QTOF LC/MS System Metabolite Identification Application Note

What is the duration of the 3T3-L1 cell differentiation process described in this study?

The differentiation process is an 8-day procedure that begins with adding a hormone cocktail to pre-adipocytes.

From: Agilent Lipidomics Discovery Profiling Targeted LC/MS Analysis in 3T3-L1 Differentiating Adipocytes Application Note

What are the dimensions of the Gemini C18 reversed phase column used for negative ion mode runs?

The column used for negative ion mode runs has dimensions of 4.6 x 50 mm.

From: Agilent Lipidomics Discovery Profiling Targeted LC/MS Analysis in 3T3-L1 Differentiating Adipocytes Application Note

What is the mass accuracy for a 10 ppb imidacloprid standard?

The mass accuracy was 1.76 ppm.

From: Agilent Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 3: Imidacloprid and Manool Application Note

What is the flow rate used during sample analysis?

The flow rate was set to 0.5 mL/min.

From: Agilent Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 3: Imidacloprid and Manool Application Note