Agilent ZORBAX Eclipse Plus C8 Manuals

ManualLib has 3 documents for the Agilent ZORBAX Eclipse Plus C8: 2 datasheets, 1 product leaflet. Every file can be read online or downloaded as a PDF for free.

Datasheet 2Product Leaflet 1

Key facts

Brand
Agilent
Model
ZORBAX Eclipse Plus C8
Documents
3
Languages
EN
Last added
2012-07-04

Start here

Agilent ZORBAX Eclipse Plus C8 Rapid Resolution HT Threaded Column Datasheet

Agilent ZORBAX Eclipse Plus C8 Rapid Resolution HT Threaded Column Datasheet

Datasheet 2 pages · 64 KB · EN

The Agilent ZORBAX Eclipse Plus C8 Rapid Resolution HT threaded columns are engineered for high-pressure operation up to 600 bar. They feature a high-performance microparticulate C8 packing bonded to an ultra-high purity ZORBAX Rx-SIL porous silica support. This design ensures superior peak shape for basic compounds and delivers high efficiency across various sample types.

Read online

Agilent ZORBAX Eclipse Plus C8 specifications

Maximum operating pressure600 bar (9,000 psi)
Maximum operating temperature60 °C
pH range2 to 8
Particle size1.8 um
Pore size95A

Source: Agilent ZORBAX Eclipse Plus C8 Rapid Resolution HT Threaded Column Datasheet

All Agilent ZORBAX Eclipse Plus C8 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum operating pressure for these columns?

The maximum operating pressure is 600 bar (9,000 psi).

From: Agilent ZORBAX Eclipse Plus C8 Rapid Resolution HT Threaded Column Datasheet

What is the recommended pH range for use?

These columns are designed for use over a pH range of 2 to 8.

From: Agilent ZORBAX Eclipse Plus C8 Rapid Resolution HT Threaded Column Datasheet

What is the Eclipse Plus C8 column especially suited for?

It is especially suited for separating basic compounds that produce poor peak shapes on other columns.

From: Agilent ZORBAX Eclipse Plus C8 Column Datasheet

What is the recommended storage solvent for long-term storage?

Long-term storage should be in a pure organic solvent, preferably an aprotic liquid such as 100% acetonitrile.

From: Agilent ZORBAX Eclipse Plus C8 Column Datasheet

Can Eclipse Plus C8 columns reduce analysis time compared to C18?

Yes, the shorter aliphatic chain of the Eclipse C8 has less hydrophobic interaction with analytes, allowing it to cut analysis time in half compared to Eclipse Plus C18.

From: Agilent ZORBAX Eclipse Plus C8 Columns Application Note

What particle sizes are available for Eclipse Plus C8?

Eclipse Plus C8 is available in 1.8, 3.5 and 5 um particle sizes for all analytical, high-resolution, and fast LC analyses.

From: Agilent ZORBAX Eclipse Plus C8 Columns Application Note