Key facts
- Brand
- Agilent
- Model
- 5975T
- Documents
- 17
- Languages
- JA · EN
- Last added
- 2012-07-06
Start here

Agilent 5975T LTM GC/MSD Operation Manual
This document is the Japanese operation manual for the Agilent 5975T LTM GC/MSD system. It provides instructions on hardware descriptions, safety warnings regarding hydrogen usage, and general operational procedures.
The guide details how to install and condition LTM column modules, operate the Electron Impact (EI) mode, and perform routine maintenance tasks such as column bake-out and ion source replacement. This manual is written in Japanese.
Agilent 5975T specifications
| Temperature ramp rate | Up to 1200 °C/min |
|---|---|
| Power consumption reduction | 50% of bench top GC/MSD |
| Footprint reduction | 38% |
| Weight reduction | 35% |
All Agilent 5975T documents by type
How to use the product for one specific task, with worked examples.
- Agilent 5975T GC/MSD Detection of Chemical Warfare Agents Application Note 6 p
- Agilent 5975T LTM GC/MSD Application Note for Determination of Volatile Aromatic Compounds in Soil by Manual SPME 6 p
- Agilent 5975T LTM GC/MSD Pesticide Detection Application Note 8 p
- Agilent 5975T LTM GC/MSD Pesticide Analysis Application Note 8 p
- Agilent 5975T LTM GC/MS Application Note for Drug Detection 8 p
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Mounting, wiring and first power-up. Read it before the hardware goes in.
- Agilent Fast Method for Determination of Nitrobenzene in Water using Agilent 5975T LTM GC/MSD Application Note
- Agilent EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace Application Note
- Agilent 5975T LTM GC/MSD Site Preparation Guide
- Agilent 5975T LTM GC/MSD Hydrogen Safety
- Agilent 5975T LTM GC/MSD Troubleshooting Maintenance Guide
- Agilent 5975T LTM GC/MSD system Manual
Questions answered in these manuals
What is the mass range of the Agilent 5975T LTM GC/MSD?
The system supports a mass range of 1.8u to 1050u.
How much time can be saved by using the vacuum maintenance technology?
Using this technology saves more than 1 hour compared to conventional systems.
What is the primary advantage of the Agilent 5975T LTM GC/MSD?
It delivers lab-quality reliability and high performance in a compact, transportable form factor suitable for field deployment.
Is the Agilent 5975T suitable for both lab and field use?
Yes, it is designed to be used for daily routine analysis in the lab as well as rapid on-site monitoring in the field.
What chemical warfare agents can this system detect?
The system is capable of rapidly separating mixtures containing O-isopropyl methylphosphonofluoridate (GB, or sarin), O-pinacolyl methylphosphonofluoridate (GD, or soman), bis(2-chloroethyl) sulfide (HD, or sulfur mustard), cyclohexyl methylphosphonofluoridate (GF), and O-ethyl S-(2-diisopropylaminoethyl) methylphosphonothiolate (VX).
From: Agilent 5975T GC/MSD Detection of Chemical Warfare Agents Application Note
How long does it take to complete a separation?
Separations are completed in less than three minutes using rapid column temperature programming.
From: Agilent 5975T GC/MSD Detection of Chemical Warfare Agents Application Note