Agilent 7890A GC Manuals

ManualLib has 20 documents for the Agilent 7890A GC (Other): 1 other, 14 application notes, 1 product leaflet, 2 user manuals, 1 quick start guide. Every file can be read online or downloaded as a PDF for free.

Other 1Application Note 14Product Leaflet 1User Manual 2Quick Start Guide 1

Key facts

Brand
Agilent
Model
7890A GC
Category
Other
Documents
20
Languages
EN · ZH
Last added
2012-07-05

Start here

Agilent 7890A GC Quick Reference

Agilent 7890A GC Quick Reference

Quick Start Guide 34 pages · 1.9 MB · EN

This document serves as a quick reference for the Agilent 7890A Gas Chromatograph. It provides an overview of available online user documentation, including safety guides, operating manuals, and troubleshooting details found on the accompanying hardware DVD.

The guide details the functions of the instrument's keypad, status board, and various keys such as Run, Info, Status, and Service Mode. Additionally, it outlines a simplified 10-step installation procedure for setting up the gas chromatograph.

Read online

Agilent 7890A GC specifications

Sample Volume10-mL water samples
Vial Type20-mL headspace vial
Internal Standard Concentration800 ng/L (800 ppt)
Target Analytes60 target analytes
Calibration Levels45 to 1,250 ng/L
Column TypeDB-624, 20 m x 0.18 mm
Carrier GasHe, constant pressure (95 kPa)
Run Time25-min run

Source: Agilent 7890A GC/5975C MSD VOC Analysis Application Note

All Agilent 7890A GC documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What is the required injection volume for the LC conditions described in the table?

The LC conditions specify an injection volume of 0.200 mL/min.

From: Agilent 1260 Infinity LC and 7890A GC Online Coupling Technical Overview

What is the initial temperature setting for the GC oven temperature program?

The GC oven temperature program starts at an initial temperature of 40 °C for 2 min.

From: Agilent 1260 Infinity LC and 7890A GC Online Coupling Technical Overview

What system was used for the analysis?

The analyses were performed on an Agilent 7890A GC/5975C MSD system.

From: Agilent 7890A GC/5975C MSD VOC Analysis Application Note

What reference water was used for calibration?

Bottled drinking water (Evian) was used for reference water blanks.

From: Agilent 7890A GC/5975C MSD VOC Analysis Application Note

What is the detection limit for sulfur compounds using this method?

The detection limits for sulfur compounds achieved the ppb level.

From: Agilent G6603A DP SCD on 7890A GC Application Note for ASTM D5504

What are the burner and reaction cell vacuum settings for the SCD?

The burner vacuum is set to 372 torr and the reaction cell vacuum is 5 torr.

From: Agilent G6603A DP SCD on 7890A GC Application Note for ASTM D5504