Agilent 6410 triple quadrupole LC Manuals

ManualLib has 4 documents for the Agilent 6410 triple quadrupole LC: 3 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 3

Key facts

Brand
Agilent
Model
6410 triple quadrupole LC
Documents
4
Languages
EN
Last added
2012-07-02

Start here

Agilent Improving Productivity in the Determination of Parameters for Early In Vitro ADME Part 4

Agilent Improving Productivity in the Determination of Parameters for Early In Vitro ADME Part 4

Application Note 4 pages · 181 KB · EN

This document describes the experimental details and results of a plasma protein binding (PPB) assay designed for early in vitro ADME profiling. The study utilizes Agilent's rapid resolution liquid chromatography (RRLC) and triple quadrupole mass spectrometry (LC/MS/MS) systems, specifically the 1200 Series RRLC, 6410 triple quadrupole LC/MS, CTC HTC-PAL autosampler, and ZORBAX RRHT column.

The note outlines the equilibrium dialysis protocol, including sample preparation, incubation conditions, and the specific MRM method setup for various test compounds. It presents a summary of results showing the fraction unbound and recovery percentages for several compounds in human plasma.

Read online

Agilent 6410 triple quadrupole LC specifications

Test compound summary concentration5 uM
Final DMSO concentration0.5 %
Final ISTD concentration0.18 pM
Plasma typeHuman
Phosphate buffer concentration0.1 M
Incubation temperature37°C
Incubation timeovernight
Final Volume130 pl
Centrifugation temperature4 °C

Source: Agilent Improving Productivity in the Determination of Parameters for Early In Vitro ADME Part 4

All Agilent 6410 triple quadrupole LC documents by type

Questions answered in these manuals

What equipment is used in the PPB assay described?

The study uses Agilent Equipment: 1200 Series RRLC, 6410 triple quadrupole LC/MS, CTC HTC-PAL autosampler, ZORBAX RRHT column, and MassHunter workstation software.

From: Agilent Improving Productivity in the Determination of Parameters for Early In Vitro ADME Part 4

What was the incubation temperature for the plasma protein binding assay?

The incubation temperature was set to 37°C.

From: Agilent Improving Productivity in the Determination of Parameters for Early In Vitro ADME Part 4

What is the final concentration of test compounds in the Caco-2 permeability assay?

The final concentration for the test compound is 10 uM.

From: Agilent Improving Productivity in Early In Vitro ADME Part 3 Caco-2 Permeability Assay Application Note

What is the maximum allowed DMSO concentration in the assay?

The final DMSO concentration must be 1.0%.

From: Agilent Improving Productivity in Early In Vitro ADME Part 3 Caco-2 Permeability Assay Application Note

What is the concentration range for lovastatin quantification?

The method covers a wide range of 0.1 ppb to 50 ppb of lovastatin in human plasma.

From: Agilent 6410 Triple Quadrupole LC/MS System Application Note: Quantification of Lovastatin in Human Plasma

What is the runtime for the analysis?

The method achieves a short runtime of approximately 1.2 minutes.

From: Agilent 6410 Triple Quadrupole LC/MS System Application Note: Quantification of Lovastatin in Human Plasma