Metabolite Identification Using ACD Labs Version 8.0 Software and the Agilent 1100 LC/MSD Trap XCT Plus System Applicati

Metabolite Identification Using ACD Labs Version 8.0 Software and the Agilent 1100 LC/MSD Trap XCT Plus System Applicati

Application Note 10 pages · 4.6 MB · EN

This document details the use of ACD Labs MS Manager Suite Version 8.0 in conjunction with an Agilent 1100 Series LC/MSD Trap XCT Plus ion trap mass spectrometer for metabolite identification studies.

The text outlines a workflow involving data import from multiple instruments, automatic comparison of control and sample data using the CODA algorithm, and structural analysis via ChemSketch. It also covers in-silico fragmentation modeling to assign structural features to mass spectral peaks.

Read online

Agilent 1100 LC specifications

Limit of Detection (LOD)0.1 ppb in shrimp and honey
Column TypeEclipse XDB C18, 4.6 mm x 180 mm, 5 um
Flow-rate0.9 mL/min
Injection Volume100 uL

Source: Chloramphenicol Detection in Honey and Shrimp Using Agilent 1100 LC/MSD Trap Application Note

All Agilent 1100 LC documents by type

Questions answered in these manuals

What software modules are included in the ACD Labs MS Manager Suite?

The suite includes MS Manager, ChroManager, UVIR Manager, MS Fragmenter, ChemSketch, SpecDB, ChemFolder, ChemBasic, HNMR Viewer, and CNMR Viewer.

From: Metabolite Identification Using ACD Labs Version 8.0 Software and the Agilent 1100 LC/MSD Trap XCT Plus System Applicati

Which instrument was used to acquire the data in this note?

The data was acquired using an Agilent LC/MS system consisting of an Agilent 1100 Series solvent degasser, binary pump, well plate sampler, thermostatted column compartment, and an Agilent 1100 Series LC/MSD XCT Plus ion trap mass spectrometer.

From: Metabolite Identification Using ACD Labs Version 8.0 Software and the Agilent 1100 LC/MSD Trap XCT Plus System Applicati

What is the duration of this training course?

The course lasts for four days.

From: Agilent 1100 LC/MSD Ion Trap Techniques and Software Operation Course Handbook

Which operating systems are required to run the equipment used in training?

Computers must have Microsoft Windows NT or 2000 installed.

From: Agilent 1100 LC/MSD Ion Trap Techniques and Software Operation Course Handbook

Which Agilent instruments are used for this analysis?

The method uses the Agilent 1100 LC/MSD Trap and the Agilent 1100 LC/MSD quadrupole mass spectrometer.

From: Chloramphenicol Detection in Honey and Shrimp Using Agilent 1100 LC/MSD Trap Application Note

What is the detection limit for chloramphenicol in honey and shrimp?

The method achieves a limit of detection at or below 0.1 ppb in both shrimp and honey.

From: Chloramphenicol Detection in Honey and Shrimp Using Agilent 1100 LC/MSD Trap Application Note