Agilent 6410B Manuals

ManualLib has 3 documents for the Agilent 6410B (Other Electronics): 3 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 3

Key facts

Brand
Agilent
Model
6410B
Documents
3
Languages
EN
Last added
2012-07-02

Start here

Agilent 6410B Triple Quadrupole LC/MS Application Note

Agilent 6410B Triple Quadrupole LC/MS Application Note

Application Note 12 pages · 867 KB · EN

This document details the use of the Agilent 6410B Triple Quadrupole LC/MS system for detecting and identifying pharmaceutical drug metabolites. It explains the operation of the triple quadrupole instrument, which consists of three quadrupoles where Q1 and Q3 act as mass filters and Q2 acts as a collision cell for fragmentation.

The note covers specific scan modes including full scan, selected ion monitoring (SIM), product ion scan, precursor ion scan, neutral loss scan, and multiple reaction monitoring (MRM). It provides experimental details for analyzing the parent drug buspirone and its metabolites using the Agilent 1200 Series Rapid Resolution LC system and MassHunter Workstation software.

Read online

Agilent 6410B specifications

Column dimensions2.1 x 150 mm
Particle size1.8 um
Flow rate0.5 mL/min
Column oven temperature50 C
Source modeElectrospray (ESI) in positive mode
Dry gas flow12.0 L/min
Dry temperature350 C
Capillary voltage3000 V
Fragmentor voltage180 V
Skimmer voltage60V
Collision energy30 eV
Mass range50-1000

Source: Agilent 6410B Triple Quadrupole LC/MS Application Note

All Agilent 6410B documents by type

Questions answered in these manuals

What is the function of the middle quadrupole (Q2)?

The quadrupole in the middle (Q2) acts as a collision cell for molecular fragmentation and generation of MS/MS information.

From: Agilent 6410B Triple Quadrupole LC/MS Application Note

Which software is used for data acquisition and analysis?

The Agilent MassHunter Workstation software is used for data acquisition and qualitative data analysis.

From: Agilent 6410B Triple Quadrupole LC/MS Application Note

What is the run time for this analysis method?

The developed method has a short run time of two minutes.

From: Agilent Determination of Fluvastatin in Plasma Using the Agilent 6410B Triple Quadrupole LC/MS System and Agilent 1200 S

How much plasma sample volume is required for preparation?

Fluvastatin and the internal standard were spiked into 250 µL of plasma.

From: Agilent Determination of Fluvastatin in Plasma Using the Agilent 6410B Triple Quadrupole LC/MS System and Agilent 1200 S

What is the quantification range for Impurity D using the UV method?

The UV method can quantify the impurity in the range of 2.0% to 0.03%.

From: Agilent 1200 Series RRLC and 6410B LC/MS Application Note for Impurity D Quantification

What is the limit of detection for Impurity D using the ESI/MS/MS method?

The limit of detection for Impurity D using the ESI/MS/MS method is 3 ppb.

From: Agilent 1200 Series RRLC and 6410B LC/MS Application Note for Impurity D Quantification