Agilent J&W DB-35ms UI Ultra Inert GC Column Application Note

Agilent J&W DB-35ms UI Ultra Inert GC Column Application Note

Application Note 8 pages · 1.2 MB · EN

This document details the analysis of challenging pesticide samples using the Agilent J&W DB-35ms Ultra Inert (UI) gas chromatography column. The note highlights how the column's inertness prevents peak tailing and degradation of active analytes like endrin and DDT, which are common issues in standard systems. It also emphasizes the column's midpolar phase for improved selectivity, allowing for the baseline resolution of coeluting peaks such as chlorpyrifos-methyl and methyl parathion.

Read online

Agilent W DB-35ms Ultra Inert specifications

Column Dimensions20 m x 0.18 mm, 0.18 µm
Part Number121-3822UI
Carrier GasHelium
Flow Rate1.3 mL/min
Oven Temperature Program50 °C (1.3 min), 50 °C/min to 135 °C, 15 °C/min to 200 °C, 20 °C/min to 310 °C (2.5 min), 5 min at 310 °C

Source: Agilent J&W DB-35ms UI Ultra Inert GC Column Application Note

All Agilent W DB-35ms Ultra Inert documents by type

Questions answered in these manuals

What is the part number for the Agilent J&W DB-35ms UI column?

The part number for the Agilent J&W DB-35ms UI column is 121-3822UI.

From: Agilent J&W DB-35ms UI Ultra Inert GC Column Application Note

How does the DB-35ms UI column improve analysis of active analytes?

The Ultra Inert series helps minimize column activity so that difficult and active analytes can be consistently analyzed at trace levels without degradation.

From: Agilent J&W DB-35ms UI Ultra Inert GC Column Application Note

What column is used for this analysis?

The method uses an Agilent J&W DB-35ms Ultra Inert (UI) 30 m x 0.25 mm, 0.25 pm column.

From: Agilent J&W DB-35ms Ultra Inert Application Note for Organophosphorus Residues in Olive Oil

What detection limits were achieved?

The detection limits for most of the pesticides were 10-15 ng/mL.

From: Agilent J&W DB-35ms Ultra Inert Application Note for Organophosphorus Residues in Olive Oil

What is the method detection limit for NNK in mainstream cigarette smoke using this method?

The estimated method detection limit for NNK is 0.03 ng/cig.

From: Agilent J&W DB-35ms Ultra Inert GC Column Application Note for TSNA Analysis

What is the lower limit of quantitation for NNK in this analysis?

The lower limit of quantitation for NNK is 0.087 ng/cig.

From: Agilent J&W DB-35ms Ultra Inert GC Column Application Note for TSNA Analysis