Agilent Liberty 200 Manuals

ManualLib has 3 documents for the Agilent Liberty 200: 3 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 3

Key facts

Brand
Agilent
Model
Liberty 200
Documents
3
Languages
EN
Last added
2012-06-12

Start here

Agilent Liberty 200 ICP-OES Application Note for High Alloy Steel Analysis

Agilent Liberty 200 ICP-OES Application Note for High Alloy Steel Analysis

Application Note 4 pages · 120 KB · EN

This document details the analysis of metals in high alloy steel using Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES). It highlights the advantages of ICP-OES over Spark Emission Spectroscopy and X-Ray Fluorescence for trace element analysis due to better detection limits and reduced matrix dependence. The note specifically focuses on the Agilent Liberty 200 ICP spectrometer.

Read online

Agilent Liberty 200 specifications

Focal length0.75 m
Grating1800 grooves/mm
Wavelength range160-900 nm
Resolution 1st order0.018 nm
RF Frequency40.68 MHz
Plasma power1.2 kW
Argon flow rate Plasma12L/min
Sample uptake rate1.4 mL/min

Source: Agilent Liberty 200 ICP-OES Application Note for High Alloy Steel Analysis

All Agilent Liberty 200 documents by type

Questions answered in these manuals

What instrument was used for the analysis?

An Agilent Liberty 200 ICP spectrometer was used for all measurements.

From: Agilent Liberty 200 ICP-OES Application Note for High Alloy Steel Analysis

What is the integration time for the analysis?

The integration time is set to 3 seconds.

From: Agilent Liberty 200 ICP-OES Application Note for High Alloy Steel Analysis

What is the maximum dissolved solids content of seawater that can be analyzed using this method?

The dissolved solids content of seawater can be up to 3.5% w/v.

From: Agilent Liberty 200 ICP-OES Analysis of Urine and Seawater Application Note

What is the sample uptake rate for the instrument system described in this application note?

The sample uptake rate is 1.8 mL/min.

From: Agilent Liberty 200 ICP-OES Analysis of Urine and Seawater Application Note

What is the maximum number of replicates used for each sample analysis?

The study analyzed each sample in triplicate.

From: Agilent Liberty 200 ICP-OES Application Note for Determination of Metals in Oils

How long does it take to analyze 12 metals with three replicates?

The Liberty could analyze the 12 metals with 3 replicates in approximately 6 minutes 30 seconds.

From: Agilent Liberty 200 ICP-OES Application Note for Determination of Metals in Oils