Key facts
- Brand
- Agilent
- Model
- 1100 Series LC
- Documents
- 23
- Languages
- EN
- Last added
- 2012-07-05
Start here

Agilent 1100 Series LC Upgrade to 1200 Series Technical Note
This document outlines a step-by-step procedure to upgrade an Agilent 1100 Series LC system to a fully equipped Agilent 1200 Series Rapid Resolution LC (RRLC) system. The upgrade process involves replacing specific components, such as the column, detector, and column compartment, to achieve higher performance metrics.
Read onlineAgilent 1100 Series LC specifications
| Time between Injections | 0.8 min |
|---|---|
| Fragmentor voltage range | 30-150 volts |
| APCI vaporizer temperature range | 300-500°C |
| Capillary voltage range | 2500-5000 volts |
| APCI corona current range | 2-10 microamps |
| Drying gas temperature range | 150-350°C |
| Drying gas flow rate range | 3-13 L/min |
| Nebulizing gas pressure range | 10-60 psig |
All Agilent 1100 Series LC documents by type
- Agilent 1100 Series LC Upgrade to 1200 Series Technical Note 8 p
- Step-by-step upgrade of Agilent 1100 to 1200 Series Rapid Resolution LC systems Technical Note 8 p
- Agilent 1100 Series LC/MSD Trap Technical Note on CID Voltage Ramping 6 p
- Optimizing LC/MSD Acquisition Parameters for Positive/Negative Mode Switching Technical Note 5 p
- Agilent Method development on the Agilent 1290 Infinity LC using Intelligent System Emulation Technology (ISET) with subsequent transfer to an Agilent 1100 Series LC Manual 8 p
- Agilent 1100 Series LC/MSD Techniques Software Operation (H1181A) handbook 1 p
- Agilent 1100 Series LC Troubleshooting Maintenance (H8969A) 1 p
How to use the product for one specific task, with worked examples.
- Agilent 1100 Series LC/MSD Technical Note 4 p
- Agilent 1100 Series LC/MSD Autotune Function and Gain Calibration Technical Note 5 p
- Agilent 1100 Series LC/MSD Application Note: Structure Elucidation of Amoxicillin Degradation Products 12 p
- Identification of Dextromethorphan Metabolites in Urine Application Note 8 p
- Agilent Structure Elucidation of Amoxicillin Degradation Products Application Note 12 p
- Agilent Fast Ultra-Fast Analysis Using the Agilent 1200 Series Rapid Resolution LC System Compared to a Conventional Agilent 1100 Series LC System 8 p
- Agilent More speed better resolution lower LOD using liquid chromatography fluorescence detection - Comparing the 1100 Series LC to the 1200 Series Rapid Resolution system 4 p
- Agilent 1100 Series LC Systems Analysis of Beta-Blocking Drugs Application Note 12 p
- Agilent 1100 Series LC/MSD Application Note: Rapid Quantification of an Enkephalin Analgesic in Cerebrospinal Fluid 3 p
- Agilent 1100 Series LC/MSD Trap SL Positive Negative Mode Analyses Application Note 5 p
- Agilent 1100 Series LC/MSD SL Using Software Tools to Improve the Detection of Impurities by LC/MS Application Note 5 p
- Agilent 1100 Series LC Analysis of Beta-Blocking Drugs Application Note 8 p
- Effect of Nonvolatile Buffers on the Agilent 1100 Series LC/MSD Application Note 6 p
- Agilent 1100 Series LC/MSD TOF Application Note for Sudan Red Screening 14 p
- Agilent 1100 Series LC/MSD Trap Structural Determination of Ginsenosides Using MSn Analysis Application Note 6 p
- Agilent 1100 Series LC/MSD Fumonisin Analysis Application Brief 4 p
Questions answered in these manuals
What is the maximum operating temperature for the Agilent 1200 Series thermostatted column compartment SL?
The new column compartment is designed to operate up to 100 °C.
From: Agilent 1100 Series LC Upgrade to 1200 Series Technical Note
What is the peak-to-peak noise of the Agilent 1200 Series DAD SL for this application?
The peak-to-peak noise of the Agilent 1200 Series DAD SL was 0.2928 mAU.
From: Agilent 1100 Series LC Upgrade to 1200 Series Technical Note
What is the maximum operating temperature for the new column compartment?
The Agilent 1200 Series thermostatted column compartment SL is designed to operate up to 100 °C.
From: Step-by-step upgrade of Agilent 1100 to 1200 Series Rapid Resolution LC systems Technical Note
What was the peak-to-peak noise of the Agilent 1200 Series DAD SL?
The peak-to-peak noise for this application was 0.2928 mAU.
From: Step-by-step upgrade of Agilent 1100 to 1200 Series Rapid Resolution LC systems Technical Note
What is the SmartFrag feature?
SmartFrag is a new feature built into the firmware of the Agilent 1100 Series LC/MSD Trap that uses CID voltage ramping to eliminate the need for optimizing collision energy for different compounds.
From: Agilent 1100 Series LC/MSD Trap Technical Note on CID Voltage Ramping
How does CID voltage ramping improve fragmentation?
It quickly ramps the collision voltage over a range of energies each time MS/MS is performed, ensuring that each compound receives the correct energy for optimum fragmentation.
From: Agilent 1100 Series LC/MSD Trap Technical Note on CID Voltage Ramping