Agilent 1100 HPLC Manuals

ManualLib has 2 documents for the Agilent 1100 HPLC: 1 other, 1 application note. Every file can be read online or downloaded as a PDF for free.

Other 1Application Note 1

Key facts

Brand
Agilent
Model
1100 HPLC
Documents
2
Languages
EN
Last added
2012-07-02

Start here

Agilent Technologies Use of Temperature to Increase Resolution in the Ultrafast HPLC Separation of Proteins with ZORBAX Poroshell 300SB-C8 HPLC Columns. Optimization of the Agilent 1100 HPLC System f

Agilent Technologies Use of Temperature to Increase Resolution in the Ultrafast HPLC Separation of Proteins with ZORBAX Poroshell 300SB-C8 HPLC Columns. Optimization of the Agilent 1100 HPLC System f

Other 8 pages · 676 KB · EN

This document provides a technical overview of optimizing the Agilent 1100 HPLC system for the separation of proteins and peptides using ZORBAX Poroshell superficially porous particle technology. It highlights how this technology allows for faster separations with reduced peak broadening compared to totally porous particles, even at higher flow rates. The text explains the mechanism of the Poroshell particle structure, which consists of a porous silica crust around a nonporous core, enabling molecules to diffuse in and out quickly.

Read online

Agilent 1100 HPLC specifications

Column (Analytical)150 x 3.0 mm ZORBAX SB-C18, 5 µm
Column (Semipreparative)50 x 9.4 mm ZORBAX SB-C18, 5 µm
Flow rate (Semipreparative)7.0 mL/min

Source: Agilent 1100 LC/MSD Application Note: Identification and Isolation of DSP-Toxins

All Agilent 1100 HPLC documents by type

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

How should flow rate be adjusted when switching from a 2.1-mm to a 1.0-mm i.d. column?

The flow rate should be reduced 5-fold to maintain the same relative flow rate (linear velocity).

From: Agilent Technologies Use of Temperature to Increase Resolution in the Ultrafast HPLC Separation of Proteins with ZORBAX Poroshell 300SB-C8 HPLC Columns. Optimization of the Agilent 1100 HPLC System f

What is the maximum operating temperature for ZORBAX Poroshell 300SB-C18 columns?

The columns are stable at temperatures up to 80 °C.

From: Agilent Technologies Use of Temperature to Increase Resolution in the Ultrafast HPLC Separation of Proteins with ZORBAX Poroshell 300SB-C8 HPLC Columns. Optimization of the Agilent 1100 HPLC System f

What toxins are identified in this application note?

The document focuses on Okadaic Acid (OA) and Dinophysistoxin-1 (DTX-1).

From: Agilent 1100 LC/MSD Application Note: Identification and Isolation of DSP-Toxins

How much does the detection limit improve with LC/MS?

Detection limits are decreased by a factor of 3-5 compared to LC with fluorescence detection.

From: Agilent 1100 LC/MSD Application Note: Identification and Isolation of DSP-Toxins