Key facts
Start here

Agilent 7500 Series ICP-MS General Features Technical Note
Agilent Technologies has produced the 7500a, 7500i, and 7500s models of the 7500 series Inductively Coupled Plasma Mass Spectrometer (ICP-MS). These instruments are designed around a single powerful and robust analytical platform, sharing basic strengths in design and performance optimized for different analytical needs.
The document details key features such as the low flow nebulizer and wide diameter injector torch for high tolerance to dissolved solids, the Omega II off-axis lens system for high ion transmission, and a precision ground profiled molybdenum quadrupole. It also highlights the new simultaneous pulse counting and analog detector, which provides a linear dynamic range of up to nine orders of magnitude.
Agilent 7500i specifications
| RF Generator Frequency | 27.12MHz |
|---|---|
| Quadrupole Drive Frequency | 3.0MHz |
| Analog Mode Settle Time | 200usecs |
Source: Agilent 7500 Series ICP-MS General Features Technical Note
All Agilent 7500i documents by type
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What are the specific models in the Agilent 7500 series?
The series includes the 7500a, 7500i, and 7500s models.
From: Agilent 7500 Series ICP-MS General Features Technical Note
What is the purpose of the 'soft extraction' mode?
It allows for exceptionally low Background Equivalent Concentrations (BECs) for ultra pure materials.
From: Agilent 7500 Series ICP-MS General Features Technical Note
Can fusion beads prepared for XRF be used for LA-ICP-MS?
Yes, the same fusion beads prepared for X-ray-fluorescence (XRF) analysis can be used for LA-ICP-MS analysis without additional sample preparation.
From: Agilent 7500i ICP-MS Application Note: LA-ICP-MS Analysis of Rare Earth Elements
What is the main advantage of this method?
The method reduces the use of expensive chemicals because only one chemical sample preparation procedure is necessary.
From: Agilent 7500i ICP-MS Application Note: LA-ICP-MS Analysis of Rare Earth Elements
What instrument is used for mercury determination in this method?
The method uses a 7500i ICP-MS.
From: Agilent 7500i ICP-MS Mercury Determination Application Note
How is memory effect avoided during analysis?
Gold is added offline to all standards, samples, and wash solutions to act as a cleansing agent.
From: Agilent 7500i ICP-MS Mercury Determination Application Note
