Agilent ZORBAX SB-C18 Manuals

ManualLib has 13 documents for the Agilent ZORBAX SB-C18 (Other Electronics): 7 product leaflets, 2 datasheets, 3 application notes. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 7Datasheet 2Application Note 3

Key facts

Brand
Agilent
Model
ZORBAX SB-C18
Documents
13
Languages
EN
Last added
2012-07-05

Start here

Agilent Ultra-fast liquid chromatography using the Agilent 1100 Series HPLC system 1.8-um ZORBAX SB C18 Rapid Resolution HT columns Manual

Agilent Ultra-fast liquid chromatography using the Agilent 1100 Series HPLC system 1.8-um ZORBAX SB C18 Rapid Resolution HT columns Manual

Product Leaflet 12 pages · 556 KB · EN

This document describes the recommended system configuration to achieve very fast analysis and cycle times using ZORBAX 1.8-um Rapid Resolution High Throughput (RRHT) columns on the Agilent 1100 Series liquid chromatograph. It details how to reduce analysis time to seconds without compromising resolution or chromatographic performance.

Read online

Agilent ZORBAX SB-C18 specifications

Analysis time29 seconds
Peak width0.5 seconds
Backpressure300 bar
Column particle size1.8 um
Delay volume300 pL
Injection speed< 30 seconds
Flow cell volume500-nL

Source: Agilent Ultra-fast liquid chromatography using the Agilent 1100 Series HPLC system 1.8-um ZORBAX SB C18 Rapid Resolution HT columns Manual

All Agilent ZORBAX SB-C18 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the minimum configuration for ultra-fast analysis?

The minimum configuration consists of the Agilent 1100 Series binary pump, well-plate autosampler, thermostatted column compartment, and ZORBAX 1.8-um RRHT columns.

From: Agilent Ultra-fast liquid chromatography using the Agilent 1100 Series HPLC system 1.8-um ZORBAX SB C18 Rapid Resolution HT columns Manual

What is the benefit of overlapped injections (OD)?

Overlapped injection allows the preparation of the next injection while the current injection is being completed, increasing sample throughput.

From: Agilent Ultra-fast liquid chromatography using the Agilent 1100 Series HPLC system 1.8-um ZORBAX SB C18 Rapid Resolution HT columns Manual

What is the maximum operating pressure for these columns?

The maximum operating pressure is 600 bar (9000 psi).

From: Agilent ZORBAX SB-C18 RRHT Threaded Column Datasheet

What is the recommended storage solvent for long term storage?

Long term storage should be in a pure organic solvent, preferably an aprotic liquid such as 100% acetonitrile.

From: Agilent ZORBAX SB-C18 RRHT Threaded Column Datasheet

What technology is used in the ZORBAX SB-C18 column?

It uses StableBond C18 packing made by chemically bonding a sterically-protected C18 stationary phase to high purity silica spheres.

From: Agilent ZORBAX SB-C18 Column Datasheet

What is the particle size of this column?

The column features sub-2-micron particles designed to reduce or eliminate strong adsorption.

From: Agilent ZORBAX SB-C18 Column Datasheet