Agilent PLgel 5 µm Manuals

ManualLib has 12 documents for the Agilent PLgel 5 µm: 5 product leaflets, 6 application notes. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 5Application Note 6

Key facts

Brand
Agilent
Model
PLgel 5 µm
Documents
12
Languages
EN
Last added
2012-07-05

Start here

Agilent PLgel 5 um MIXED-D Columns Technical Overview

Agilent PLgel 5 um MIXED-D Columns Technical Overview

Product Leaflet 2 pages · 67 KB · EN

The PLgel 5 um MIXED-D column is specifically designed for the analysis of polymers, paints, and resin systems where material above 400,000 MW is unlikely to be present. It features high pore volume combined with 5 um efficiency to provide excellent resolution for low molecular weight polymers and oligomers.

Read online

Agilent PLgel 5 µm specifications

Particle Size5 um
Pore VolumeHigh pore volume
Target Molecular WeightBelow 400,000 MW
Recommended Column Set2 x PLgel 5 um MIXED-D, 300 x 7.5 mm
Recommended EluentTHF
Recommended Flow Rate1.0 mL/min
Detection MethodRI

Source: Agilent PLgel 5 um MIXED-D Columns Technical Overview

All Agilent PLgel 5 µm documents by type

Questions answered in these manuals

What types of materials is the PLgel 5 um MIXED-D column designed to analyze?

The column is specifically designed for analyzing polymers, paints, and resin systems where material above 400,000 MW is unlikely to be present.

From: Agilent PLgel 5 um MIXED-D Columns Technical Overview

What are the dimensions of the column used in the example resin analysis?

The example analysis uses a column with dimensions of 300 x 7.5 mm.

From: Agilent PLgel 5 um MIXED-D Columns Technical Overview

What types of materials are these columns designed to analyze?

The PLgel 5 um MIXED-D column is specifically designed for the analysis of polymers, paints and resin systems.

From: Agilent PLgel 5 um MIXED-D Columns Technical Overview

What is the recommended flow rate for using these columns?

The recommended flow rate for the analysis is 1.0 mL/min.

From: Agilent PLgel 5 um MIXED-D Columns Technical Overview

What is the PLgel 5 um MIXED-D column designed for?

It is designed for the analysis of polymers, paints, and resin systems where material above 400,000 MW is unlikely to be present.

From: Agilent PLgel 5 um MIXED-D Columns Technical Overview

Why are PLgel 5 um MIXED-D columns ideal for condensation polymers?

Because polymers produced by condensation polymerization rarely contain material above 400,000 molecular weight.

From: Agilent PLgel 5 um MIXED-D Columns Technical Overview