Agilent 7000 Triple Quadrupole GC Manuals

ManualLib has 2 documents for the Agilent 7000 Triple Quadrupole GC (Other): 2 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 2

Key facts

Brand
Agilent
Model
7000 Triple Quadrupole GC
Category
Other
Documents
2
Languages
EN
Last added
2012-07-02

Start here

Agilent 7000 Triple Quadrupole GC/MS Estradiol Detection Application Brief

Agilent 7000 Triple Quadrupole GC/MS Estradiol Detection Application Brief

Application Note 6 pages · 166 KB · EN

This document details a method developed on the Agilent 7890GC/7000 Triple Quadrupole GC/MS system to detect and quantify estradiol in human plasma. The method achieves a limit of detection (LOD) of 1 pg/mL (2 fg on-column) and maintains a relative standard deviation (RSD) for quantification of less than 15% across a concentration range of 1 to 600 pg/mL. The analysis utilizes the MS/MS-NCI (negative chemical ionization) mode with a specific column and injection sequence.

Read online

Agilent 7000 Triple Quadrupole GC specifications

Limit of Detection (LOD)1 pg/mL (2 fg on-column)
Quantification Range1 to 600 pg/mL
Relative Standard Deviation (RSD)<15%
Analytical Column15m x 0.25 mm x 0.25 pm Agilent J&W DB-5MS UI
Carrier GasHelium, constant flow, 1.2 mL/min
MS ModeNCI mode; 40% ammonia
Source Temperature150 °C
Quadrupoles Temperature150 °C
Collision Gas FlowsNitrogen at 1.5 mL/min, Helium at 2.35 mL/min
Total Run Time2.85 minutes

Source: Agilent 7000 Triple Quadrupole GC/MS Estradiol Detection Application Brief

All Agilent 7000 Triple Quadrupole GC documents by type

Application Note 2

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What is the limit of detection for estradiol using this method?

The limit of detection is 1 pg/mL, which corresponds to 2 fg injected on-column.

From: Agilent 7000 Triple Quadrupole GC/MS Estradiol Detection Application Brief

What is the quantification range for estradiol?

The method provides quantification for estradiol in the range of 1 to 600 pg/mL.

From: Agilent 7000 Triple Quadrupole GC/MS Estradiol Detection Application Brief

What instrument is used for this analysis?

The analysis is performed on an Agilent 7890 GC coupled with an Agilent 7000 Triple Quadrupole GC/MS system.

From: Agilent 7000 Triple Quadrupole GC/MS PCB Analysis Application Note

What is the detection limit for dioxin-like PCB congeners in this method?

The method provides quantitative results for dioxin-like PCB congeners down to low pg TEQ/g levels.

From: Agilent 7000 Triple Quadrupole GC/MS PCB Analysis Application Note