Agilent 500-MS Ion Trap LC Manuals

ManualLib has 3 documents for the Agilent 500-MS Ion Trap LC: 3 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 3

Key facts

Brand
Agilent
Model
500-MS Ion Trap LC
Documents
3
Languages
EN
Last added
2012-06-12

Start here

Agilent Application Note 01636: Mass Spectrometry With Evaporative Light Scattering Detection for Pharmaceuticals

Agilent Application Note 01636: Mass Spectrometry With Evaporative Light Scattering Detection for Pharmaceuticals

Application Note 3 pages · 169 KB · EN

This document describes an analytical method combining Mass Spectrometry (MS) with Evaporative Light Scattering Detection (ELSD). It addresses limitations in standard MS analysis, such as poor ionization of certain analytes and matrix effects. The note details how coupling these detectors allows for simultaneous detection or serial/selected detection using a divert valve.

Three specific pharmaceutical applications are presented: the analysis of Haloperidol and its metabolites, the differentiation of Diazepam and Verapamil responses, and the quantitation of Ibuprofen in the presence of B-cyclodextrin. The text provides specific instrument configurations, HPLC conditions, and parameter settings for both the MS and ELSD systems.

Read online

All Agilent 500-MS Ion Trap LC documents by type

Questions answered in these manuals

How does ELSD compare to MS in terms of response for Diazepam and Verapamil?

While these compounds show significantly different responses in full scan MS, they exhibit a relatively equal response in the ELSD detector.

From: Agilent Application Note 01636: Mass Spectrometry With Evaporative Light Scattering Detection for Pharmaceuticals

What is the flow rate range compatible with ESI or APCI for this system?

The ELSD has similar operating parameters to LC/MS, utilizing flow rates in the range of 0.2-0.5 mL/min.

From: Agilent Application Note 01636: Mass Spectrometry With Evaporative Light Scattering Detection for Pharmaceuticals

What is the purpose of this application note?

This document describes a method to separate and analyze the components of the Ethomeen T/20H emulsifier using LC/MS.

From: Agilent 500-MS Ion Trap LC/MS Application Note for Ethomeen T/20H Characterization

What instrument is used for the analysis?

The analysis uses a Varian 500-MS Ion Trap LC/MS equipped with an ESI source.

From: Agilent 500-MS Ion Trap LC/MS Application Note for Ethomeen T/20H Characterization

What is the total run time for the analysis method?

The method is completed in less than five minutes.

From: Agilent 500-MS Ion Trap LC/MS Analysis of Isocyanate Derivatives Application Note

What is the lowest limit of detection reported for any compound?

The lowest limit of detection is 75 ppt for HDI.

From: Agilent 500-MS Ion Trap LC/MS Analysis of Isocyanate Derivatives Application Note