Agilent 1100 LC Manuals

ManualLib has 10 documents for the Agilent 1100 LC: 1 quick start guide, 8 application notes, 1 other. Every file can be read online or downloaded as a PDF for free.

Quick Start Guide 1Application Note 8Other 1

Key facts

Brand
Agilent
Model
1100 LC
Documents
10
Languages
ZH · EN
Last added
2026-11-17

Start here

Agilent 1100 LC ChemStation Software Quick Start Guide

Agilent 1100 LC ChemStation Software Quick Start Guide

Quick Start Guide 50 pages · 1.6 MB · ZH

This quick start manual gives operating steps for the Agilent ChemStation software used with an Agilent 1100 LC system. It is manual part number G2170-97701, edition January 2005, and applies to software version B.01.01C.

The manual is arranged as five exercises: equilibrating the system, building a method for an analysis check sample, integrating signals, establishing calibration, and automated analysis. The equilibration exercise uses the Agilent isocratic sample (part number 01080-68702), with solvent channel A water and channel B acetonitrile, and recommends a Zorbax Eclipse XDB C-8 column, 150 mm x 4.6 mm, 5 µm, part number 993967-906. This manual is written in Chinese.

Read online

Agilent 1100 LC specifications

Software versionB.01.01C
Recommended column for Agilent isocratic sampleZorbax Eclipse XDB C-8, 150 mm x 4.6 mm, 5 µm, part number 993967-906
Agilent isocratic sample part number01080-68702
Solvent channelsA channel: water; B channel: acetonitrile

Source: Agilent 1100 LC ChemStation Software Quick Start Guide

All Agilent 1100 LC documents by type

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

Which software version does the manual cover?

It covers Agilent ChemStation software version B.01.01C.

From: Agilent 1100 LC ChemStation Software Quick Start Guide

Which column is recommended for the Agilent isocratic sample?

A Zorbax Eclipse XDB C-8 column, 150 mm x 4.6 mm, 5 µm, part number 993967-906.

From: Agilent 1100 LC ChemStation Software Quick Start Guide

What software modules are included in the ACD Labs MS Manager Suite?

The suite includes MS Manager, ChroManager, UVIR Manager, MS Fragmenter, ChemSketch, SpecDB, ChemFolder, ChemBasic, HNMR Viewer, and CNMR Viewer.

From: Metabolite Identification Using ACD Labs Version 8.0 Software and the Agilent 1100 LC/MSD Trap XCT Plus System Applicati

Which instrument was used to acquire the data in this note?

The data was acquired using an Agilent LC/MS system consisting of an Agilent 1100 Series solvent degasser, binary pump, well plate sampler, thermostatted column compartment, and an Agilent 1100 Series LC/MSD XCT Plus ion trap mass spectrometer.

From: Metabolite Identification Using ACD Labs Version 8.0 Software and the Agilent 1100 LC/MSD Trap XCT Plus System Applicati

What is the duration of this training course?

The course lasts for four days.

From: Agilent 1100 LC/MSD Ion Trap Techniques and Software Operation Course Handbook

Which operating systems are required to run the equipment used in training?

Computers must have Microsoft Windows NT or 2000 installed.

From: Agilent 1100 LC/MSD Ion Trap Techniques and Software Operation Course Handbook