Agilent 1100 LC ChemStation Software Quick Start Guide
This quick start manual gives operating steps for the Agilent ChemStation software used with an Agilent 1100 LC system. It is manual part number G2170-97701, edition January 2005, and applies to software version B.01.01C.
The manual is arranged as five exercises: equilibrating the system, building a method for an analysis check sample, integrating signals, establishing calibration, and automated analysis. The equilibration exercise uses the Agilent isocratic sample (part number 01080-68702), with solvent channel A water and channel B acetonitrile, and recommends a Zorbax Eclipse XDB C-8 column, 150 mm x 4.6 mm, 5 µm, part number 993967-906. This manual is written in Chinese.
Agilent 1100 LC specifications
| Software version | B.01.01C |
|---|---|
| Recommended column for Agilent isocratic sample | Zorbax Eclipse XDB C-8, 150 mm x 4.6 mm, 5 µm, part number 993967-906 |
| Agilent isocratic sample part number | 01080-68702 |
| Solvent channels | A channel: water; B channel: acetonitrile |
Source: Agilent 1100 LC ChemStation Software Quick Start Guide
All Agilent 1100 LC documents by type
The shortest path to a working setup, usually only a few pages.
How to use the product for one specific task, with worked examples.
- Metabolite Identification Using ACD Labs Version 8.0 Software and the Agilent 1100 LC/MSD Trap XCT Plus System Applicati 10 p
- Agilent 1100 LC/MSD Therapeutic Drug Monitoring Application Note: Clozapine Example 8 p
- Agilent 1100 LC/MSD Performance-Based Mass Spectral Library Application Note 14 p
- Agilent Determination of LSD iso-LSD 2-Oxo-3-Hydroxy-LSD in Urine Using the HP1100 LC/MSD 4 p
- Agilent 1100 LC/MS Analysis of Simazine Thiobencarb Thiuram 2 p
- Agilent 1100 LC/MSD Application Note: Identification and Isolation of DSP-Toxins 8 p
- Chloramphenicol Detection in Honey and Shrimp Using Agilent 1100 LC/MSD Trap Application Note 10 p
- Agilent 1100 LC/MS Analysis of Triglycerides Application Note 4 p
Questions answered in these manuals
Which software version does the manual cover?
It covers Agilent ChemStation software version B.01.01C.
From: Agilent 1100 LC ChemStation Software Quick Start Guide
Which column is recommended for the Agilent isocratic sample?
A Zorbax Eclipse XDB C-8 column, 150 mm x 4.6 mm, 5 µm, part number 993967-906.
From: Agilent 1100 LC ChemStation Software Quick Start Guide
What software modules are included in the ACD Labs MS Manager Suite?
The suite includes MS Manager, ChroManager, UVIR Manager, MS Fragmenter, ChemSketch, SpecDB, ChemFolder, ChemBasic, HNMR Viewer, and CNMR Viewer.
Which instrument was used to acquire the data in this note?
The data was acquired using an Agilent LC/MS system consisting of an Agilent 1100 Series solvent degasser, binary pump, well plate sampler, thermostatted column compartment, and an Agilent 1100 Series LC/MSD XCT Plus ion trap mass spectrometer.
What is the duration of this training course?
The course lasts for four days.
From: Agilent 1100 LC/MSD Ion Trap Techniques and Software Operation Course Handbook
Which operating systems are required to run the equipment used in training?
Computers must have Microsoft Windows NT or 2000 installed.
From: Agilent 1100 LC/MSD Ion Trap Techniques and Software Operation Course Handbook