Agilent 7500 Series ICP-MS Basic Introduction Guide
The document serves as a fundamental introduction to Inductively Coupled Plasma Mass Spectrometry (ICP-MS), specifically focusing on the Agilent 7500 Series. It covers the historical development of the technology, its basic operating principles including hardware design and ionization processes, and various methods for controlling interferences. This manual is written in Chinese.
Read onlineAgilent 7500 Series specifications
| Dimensions (WxDxH) | 1100 x 640 x 600 mm |
|---|---|
| Weight | 175Kg |
| Maximum Output Power | 1.6kW |
| Mass Range | 2-260amu |
| Operating Temperature | 15-30C |
| Operating Humidity | 60~80% |
| Power Supply (Single Phase) | 200-240V, 30A |
| Cooling Water Flow | 5L/min or more |
Source: Agilent 7500 Series ICP Mass Spectrometer Product Leaflet
All Agilent 7500 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Agilent 7500 Series ICP Mass Spectrometer Product Leaflet 6 p
- Agilent 7500 Series ICP-MS Organic Analysis Technical Feature 1 p
- Agilent Plasma Chrom Software Technical Features 4 p
- Agilent 7500 Series ICP-MS Forensic Analysis Application Note 1 p
- Agilent High Matrix Sample Introduction Accessory Performance Characteristics Manual for 7500 Series ICP-MS 6 p
- Agilent LC-ICP-MS Connection Kit for Agilent 7500 Series Product Leaflet 4 p
- Agilent 7500 Series ICP-MS Food Safety Capabilities 1 p
- Agilent 7500 Series ICP-MS Brochure 12 p
- Agilent 7500 Series ICP-MS Brochure 12 p
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What is the approximate temperature of the center channel in an ICP-MS plasma?
The center channel temperature is approximately 7500 K.
How long does it take to form ions after the aerosol enters the plasma?
These ions are formed within approximately 10 milliseconds after the aerosol enters the rear of the plasma.
What are the four models available in the Agilent 7500 Series?
The series includes models optimized for high sensitivity (FBO0s), automated dilution (FBoQI), standard wide-range analysis (FBoQQa), and octopole reaction systems (FBoQOc).
From: Agilent 7500 Series ICP Mass Spectrometer Product Leaflet
What is the mass range of the instrument?
The mass range covers from 2 to 260 amu.
From: Agilent 7500 Series ICP Mass Spectrometer Product Leaflet
What sample uptake rates does the Agilent 7500 Series support?
The system allows for low sample uptake rates between 50 and 400 ul/min.
From: Agilent 7500 Series ICP-MS Organic Analysis Technical Feature
What power level is typically used with the ShieldTorch interface?
The ShieldTorch interface enables operation under high power cool plasma conditions, typically at 900W.
From: Agilent 7500 Series ICP-MS Organic Analysis Technical Feature