Rockwell Automation MicroLogix 1400 Error Codes

209 codes from pages 76–428 of the manual

This is the list of error codes the Rockwell Automation manual gives for the MicroLogix 1400 MicroLogix 1400 Programmable Controller. Find your code below and open it for what the manual says about its causes and what to do.

Error codes from p. 76

CodeWhat it meansPage
1 Invalid File Number p. 106
2 Invalid Mode p. 106
3 Invalid High Preset p. 258
4 Invalid Overflow p. 76
5 Invalid Underflow p. 258
-3 Undefined Accel/Decel p. 106
-2 Overlap Error p. 111
-1 Output Error p. 111
0 Normal p. 106
6 Jog Frequency Error p. 106
7 Length Error p. 258
1H Loop update time O1 > 1024 p. 231
2H Proportional gain Kc < 0 p. 231
3H Integral gain (reset) T1 < 0 p. 231
4H Derivative gain (rate) Td < 0 p. 231
5H Feedforward Bias (FF) is out-of-range p. 231
23H Scaled setpoint min MinS > Scaled setpoint max MaxS p. 231
8 ERR_SOCKET_UNLISTEN p. 258
9 ERR_SOCKET_UNBIND p. 258
10 ERR_SOCKET_UNACCEPT p. 258
11 ERR_SOCKET_DISCONNECT p. 258
12 ERR_SOCKET_DELETE p. 258
13 INVALID_SERVER_TYPE p. 258
14 INVALID_TYPE_CODE p. 258
15 ERR_QUE_FULL p. 258
02H Target node is busy, NAK No Memory retries by link layer exhausted p. 310
03H Target node cannot respond because message is too large p. 310
04H Target node cannot respond because it does not understand the command parameters OR the control block may have been inadvertently modified. p. 310
05H Local processor is offline (possible duplicate node situation) p. 310
06H Target node cannot respond because the requested function is not available. p. 310
07H Target node does not respond p. 310
08H Target node does not respond. p. 310
0BH Target node does not accept this type of MSG instruction p. 310
0CH Received a master link reset (one possible source is from the DF1 master). p. 310
0FH DCOMM button was activated while an ASCII instruction was waiting to execute. p. 310
10H Target node cannot respond because of incorrect command parameters or unsupported command. p. 310
12H Local channel configuration protocol error exists p. 310
13H Local MSG configuration error in the Remote MSG parameters p. 310
15H Local channel configuration parameter error exists p. 310
16H Target or Local Bridge address is higher than the maximum node address. p. 310
17H Local service is not supported p. 310
18H Broadcast is not supported p. 310
20H PCCC Description: Host has a problem and does not communicate p. 310
21H Bad MSG file parameter for building message p. 310
30H PCCC Description: Remote station host is not there, disconnected, or shutdown. p. 310
37H Message timed out in local processor p. 310
38H Local communication channel is reconfigured while MSG active p. 310
3AH STS in the reply from the target is invalid p. 310
40H PCCC Description: Host could not complete function due to hardware fault. p. 310
46H MSG reply cannot be processed, Either Insufficient data in MSG read reply or bad network address parameter. p. 310
50H Target node is out of memory p. 310
60H Target node cannot respond because the file is protected p. 310
70H PCCC Description: Processor is in Program Mode p. 310
80H PCCC Description: Compatibility mode file missing or communication zone problem. p. 310
81H Modbus Error 1; Illegal Function p. 310
82H Modbus Error 2; Illegal Data Address p. 310
83H Modbus Error 3; Illegal Data Value p. 310
84H Modbus Error 4; Slave Device Failure p. 310
85H Modbus Error 5; Acknowledge p. 310
86H Modbus Error 6; Slave Device Busy p. 310
87H Modbus Error 7; Negative Acknowledge p. 310
88H Modbus Error 8; Memory Parity Error p. 310
90H PCCC Description; Remote station cannot buffer command p. 310
B0H PCCC Description; Remote station problem due to download p. 310
C0H No IP address configured for the network, or Bad command - unsolicited message error, or Bad address - unsolicited message error, or No privilege - unsolicited message error, or Multihop messaging cannot route request. p. 310
D0H Maximum connections used - no connections available p. 310
D2H Invalid Internet address or host name p. 310
D3H No such host exists p. 310
D4H Cannot communicate with the name server. p. 311
D5H Connection is not completed before user-specified timeout. p. 311
D6H Connection timed out by the network. p. 311
D7H Connection refused by destination host. p. 311
D8H Connection was broken. p. 311
D9H Reply not received before user-specified timeout. p. 311
DAH No network buffer space available. p. 311
DBH Multi-hop messaging CIP message-format error. p. 311
DCH Class 3 CIP connections are duplicated for the same IP address. p. 311
DDH SMTP General Error Code. The error code that is returned can be found in the upper byte of sub-element 22. p. 311
DEH CIP Object Specific General error code. The error code that is returned can be found in the upper byte of sub-element 22. p. 311
DFH Multi-hop messaging has no IP address configured for network. p. 311
E0H Expansion I/O Communication Module Error or CIP device response error code. The error code that is returned can be found in the upper byte of sub-element 22. p. 311
E1H PCCC Description; Illegal Address Format, a field has an illegal value. p. 311
E2H PCCC Description; Illegal Address format, not enough fields specified. p. 311
E3H PCCC Description; Illegal Address format, too many fields specified. p. 311
E4H PCCC Description; Illegal Address symbol not found. p. 311
E5H PCCC Description; Illegal Address format, symbol is 0 or greater than the maximum number of characters support by this device. p. 311
E6H PCCC Description; Illegal Address, address does not exist, or does not point to something usable by this command. p. 311
E7H Target node cannot respond because the length requested is too large. p. 311
E8H PCCC Description; Cannot complete the request, situation changed (file size, for example) during multi-packet operation. p. 311
E9H PCCC Description; Data or file is too large, Memory unavailable. p. 311
EAH PCCC Description; Request is too large; transaction size plus word address is too large. p. 311
EBH Target node cannot respond because target node denies access. p. 311
ECH Target node cannot respond because the requested function is currently unavailable. p. 311
EDH PCCC Description; Resource is already available; condition exists. p. 311
EEH PCCC Description; Command cannot be executed. p. 311
EFH PCCC Description; Overflow, histogram overflow. p. 311
F0H PCCC Description; No access. p. 311
F1H Local processor detects illegal target file type. p. 311
F2H PCCC Description; Invalid parameter; invalid data in search or command block. p. 311
F3H PCCC Description; Address reference exists to a deleted area. p. 311
F4H PCCC Description; Command execution failure for unknown reason PLC-3® histogram overflow. p. 311
F5H PCCC Description; Data conversion error. p. 311
F6H PCCC Description; The scanner is not able to communicate with a 1771 rack adapter. This could be due to the scanner not scanning, the selected adapter not being scanned, the adapter is not responding, or there is an invalid request of a "Demand Chain Management™ (DCM) Block Transfer [BT]". p. 311
F7H PCCC Description; The adapter is not able to communicate with a module. p. 311
F8H PCCC Description; The 1771 module response was not valid size, checksum, and so on. p. 311
FAH Target node cannot respond because another node is file owner (has sole file access). p. 311
FBH Target node cannot respond because another node is program owner (has sole access to all files). p. 311
FCH PCCC Description; Disk file is written protected or otherwise inaccessible (offline only). p. 311
FDH PCCC Description; Disk file is being used by another application update not performed (offline only). p. 311
FFH Local communication channel is shut down. p. 311
16 ERR_BUFFER_ALLOC p. 329
17 ERR_PACKET_ALLOC p. 329
18 ERR_PACKET_RELEASE p. 329
30 ERR_CONN_REJECTED p. 329
31 ERR_INVALID_HEADER_CRC p. 329
32 ERR_INVALID_HEADER p. 329
33 ERR_INVALID_PACKET_CRC p. 329
34 ERR_BAD_PACKET_RECEIVED p. 329
35 ERR_PACKET_REJECTED p. 329
36 ERR_CONNECTION_BROKEN p. 329
37 Reserved p. 329
01 NO_SOCKET p. 354
02 NO_BUFFER_AVAILABLE p. 354
03 MAX_CONNECTION p. 354
04 ILLEGAL_SEQUENCE p. 354
05 CONNECTION_BROKEN p. 354
06 ADDR_IN_USE p. 354
07 DNS_ERROR p. 354
08 FORCE_BUFFER_RETURN p. 354
19 INVALID_DATA_LENGTH p. 354
1A INVALID_TIMEOUT p. 354
20 SOCKET_ERROR_CREATE p. 354
21 SOCKET_ERROR_LISTEN p. 354
22 SOCKET_ERROR_BIND p. 354
23 SOCKET_ERROR_ACCEPT p. 354
24 SOCKET_ERROR_CONNECT p. 354
25 SOCKET_ERROR_SEND p. 354
26 SOCKET_ERROR_RECEIVE p. 354
27 SOCKET_ERROR_UNLISTEN p. 354
28 SOCKET_ERROR_UNBIND p. 354
29 SOCKET_ERROR_UNACCEPT p. 354
2A SOCKET_ERROR_DISCONNECT p. 354
2B SOCKET_ERROR_DELETE p. 354
0001 NVRAM ERROR p. 402
0002 UNEXPECTED RESET p. 402
0003 MEMORY MODULE USER PROGRAM IS CORRUPT p. 402
0004 MEMORY INTEGRITY ERROR p. 402
0006 MEMORY MODULE HARDWARE FAULT p. 402
0007 MEMORY MODULE TRANSFER ERROR p. 402
0008 FATAL INTERNAL SOFTWARE ERROR p. 402
0009 FATAL INTERNAL HARDWARE ERROR p. 402
000A OS MISSING OR CORRUPT p. 402
000B BASE HARDWARE FAULT p. 402
0011 EXECUTABLE FILE 2 IS MISSING p. 402
0012 LADDER PROGRAM ERROR p. 402
0015 I/O CONFIGURATION FILE ERROR p. 402
0016 STARTUP PROTECTION FAULT p. 402
0017 NVRAM/MEMORY MODULE USER PROGRAM MISMATCH p. 403
0018 MEMORY MODULE USER PROGRAM INCOMPATIBLE WITH OS p. 403
001A USER PROGRAM INCOMPATIBLE WITH OS AT POWER-UP p. 403
0020 MINOR ERROR AT END-OF-SCAN DETECTED p. 403
0022 WATCHDOG TIMER EXPIRED, SEE S:3 p. 403
0023 STI ERROR p. 403
0028 INVALID OR NONEXISTENT USER FAULT ROUTINE VALUE p. 403
0029 INSTRUCTION INDIRECTION OUTSIDE OF DATA SPACE p. 403
002A INVALID DNP3 AND RPC/DLS CONFIGURATION p. 403
002B DNP3 EVENTS CONFIGURATION MISMATCH p. 403
002E EI ERROR p. 403
0030 SUBROUTINE NESTING EXCEEDS LIMIT p. 403
0031 UNSUPPORTED INSTRUCTION DETECTED p. 403
0032 S00/S0C/SOL OUTSIDE OF DATA FILE SPACE p. 403
0033 BSL/BSR/FFL/FFU/LFL/FU CROSSED DATA FILE SPACE p. 403
0034 NEGATIVE VALUE IN TIMER PRESET OR ACCUMULATOR p. 403
0035 ILLEGAL INSTRUCTION IN INTERRUPT FILE p. 403
0036 INVALID PID PARAMETER p. 404
0037 HSC ERROR p. 404
0038 PTOX ERROR p. 404
003C PWMX ERROR p. 404
003D INVALID SEQUENCER LENGTH/POSITION p. 404
003E INVALID BIT SHIFT OR LIFO/FIFO PARAMETER p. 404
003F COP/CPW/FLL OUTSIDE OF DATA FILE SPACE p. 404
0042 INVALID RECIPE NUMBER p. 404
0044 INVALID WRITE TO RTC FUNCTION FILE p. 404
0050 CONTROLLER TYPE MISMATCH p. 404
0051 BASE TYPE MISMATCH p. 404
0052 MINIMUM SERIES ERROR p. 404
0061 EMBEDDED ANALOG INPUT FAULT p. 404
xx71 EXPANSION I/O HARDWARE ERROR p. 404
xx73 EXPANSION I/O MODULE ERROR p. 404
xx81 EXPANSION I/O HARDWARE ERROR p. 404
0083 MAX I/O CABLES EXCEEDED p. 404
0084 MAX I/O POWER SUPPLIES EXCEEDED p. 404
0085 MAX I/O MODULES EXCEEDED p. 404
xx8f(1) EXPANSION I/O MODULE BAUD RATE ERROR p. 405
xx87(1) I/O CONFIGURATION MISMATCH p. 405
xx89(102) EXPANSION I/O MODULE ERROR p. 405
xx8a(102) EXPANSION I/O CABLE CONFIGURATION MISMATCH ERROR p. 405
xx8b(102) EXPANSION I/O POWER SUPPLY CONFIGURATION MISMATCH ERROR p. 405
xx8c(102) EXPANSION I/O OBJECT TYPE MISMATCH p. 405
0x1F39 INVALID STRING LENGTH p. 405
81 Illegal Function p. 427
82 Illegal Data Address p. 427
83 Illegal Data Value p. 427
84 Slave Device Failure p. 427
85 Acknowledge p. 427
86 Slave Device Busy p. 427
87 Negative Acknowledge p. 427
88 Memory Parity Error p. 427
89 Non-standard Error Code p. 427